Hardware options installation 35
Locate and download the latest ROM version from the HP website Follow the instructions on the website to update the system ROM.
2.
Power down the server (on page
3.
Disconnect all peripheral cables from the server.
4.
5.
Place the server on a flat, level work surface.
6.
Remove the processor air baffle (on page
7.
Open the DIMM slot latches.
8.
Install the DIMM.
9.
Install the processor air baffle (on page
10.
Install the server into the chassis ("
" on page
11.
Connect all peripheral cables to the server.
12.
Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
If you are installing DIMMs in online spare, mirrored, or lock-step configuration, configure this mode in RBSU.
PCIe expansion board options
The server supports installation of options in the PCI riser assembly. For more information about supported
options, see the product QuickSpecs on the HP website To install the component:
1.
Power down the server (on page
2.
Disconnect all peripheral cables from the server.
3.
4.
Place the server on a flat, level work surface.
5.
Summary of Contents for ProLiant XL230a Gen9