Physical and operating specifications 78
Table 11
Hardware specifications
Item
Components
Thermal solution
Eight 80mm system fans
Table 12
Physical dimensions
Item
Description
System board platform
ATX (Advanced Technology Extended)
System board dimension
17.935’’x6.5’’
Dimensions (H x W x D)
(with bezel)
6.96 x 17.64 x 35.32 inch
Server weight (approximate)
Full loading (all memory, hard drives, power supplies, and processors
installed) 68.1kg
Light loading (one piece of memory, one hard drive, and one processor
8 trays installed) 55.2kg
Table 13
Environmental specifications
Item
Description
Thermal output (maximum operating) 392 W/hr
System inlet temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an altitude derating of
1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct sustained sunlight.
Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or
above 86°F (30°C).
System inlet temperature
Nonoperating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative humidity (noncondensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb
temperature, noncondensing.
Relative humidity (noncondensing)
Non-operating
10% to 95% relative humidity (Rh), 101.7°F (38.7°C) maximum wet
bulb temperature, noncondensing.
Altitude
Operating
10,000 ft (3050 m). This value may be limited by the type and number
of options installed. Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Altitude
Nonoperating
30,000 ft (9144 m). Maximum allowable altitude change rate is 1500
ft/min (457 m/min).