System Unit
Chassis Dimensions
(H x
W x D) Add fan extension
kit
(with bezel)
6.96 x 17.638 x 35.236in (17.68 x 44.8 x 89.55cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
220lb (99.8kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 to 140 VAC
180 to 264 VAC
Rated Input Current
7.31A at 115VAC
3.6A at 230VAC
Rated Input Frequency
47 to 63 Hz
Rated Input Power
855W (at 100 VAC),
840.72W (at 200 VAC)
Power Supply Output
(per power supply)
Rated Steady-State Power 653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet
Temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 304.8 m) above sea level to a
maximum of 10,000 ft (3048 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 86°F (30°C).
Non-operating
-22° to 140° F (-30° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
Non-operating
5% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
Altitude
Operating
10,000 ft (3048 m). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
1500 ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable
altitude change rate is 1500 ft/min (457
m/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and
declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
6.4
LpAm
45dBA