System BIOS configuration 35
Table 23
POST error message
601
Error: BMC Not Responding
Please check Front panel, System ID Jumper or Riser card
Press F1 to Continue
628
Redundant Power Supply Mismatch
194
CPUID, Processor family are different
192
L3 cache size mismatch
197
Processor speeds mismatched
198
Processor QPI speed mismatch detected.
193
CPUID, Processor stepping are different
196
CPUID, Processor Model are different
195
Front side bus mismatch. System halted.
160
Processor missing microcode
005
CMOS Checksum Bad
041
Display memory test failed
040
Refresh timer test failed
048
Password check failed
00B
CMOS Memory Size Wrong
010
Floppy Controller Failure
00C
RAM R/W test failed
003
CMOS Battery Low
701
Insufficient Runtime space for MPS data.
System may operate in PIC or Non-MPS mode.
702
No enough APIC ID in range 0-0Fh can be assigned to IO APICs.
(Re-assigning CPUs' local APIC ID may solve this issue)
MPS Table is not built! System may operate in PIC or Non-MPS mode.
120
$A0CCMOS Cleared by Jumper. Restore the Jumper and Continue.
122
$A0CPassword Cleared By Jumper. Restore the Jumper and Continue.
POST-related troubleshooting
Refer to HP ProLiant SL165s Maintenance and Service Guide for troubleshooting guidelines.