Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
with ISO 9296 (ECMA 109).
Idle
L
WAd
3.9 Bels (1P Non-Redundant)
4.2 Bels (2P Redundant)
L
pAm
22 dBA (1P Non-Redundant)
24 dBA (2P Redundant)
Operating
L
WAd
4.0 Bels (1P Non-Redundant)
4.8 Bels (2P Redundant)
L
pAm
22 dBA (1P Non-Redundant)
30 dBA (2P Redundant)
NOTE:
The Listed sound levels apply to standard shipping configurations.
Additional options may result in increased sound levels.
Emissions Classification
(EMC)
FCC Rating
Class B
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15;
ICES-003; CNS13438; GB9254; K22;K24; EN
61000-3-2; EN 61000-3-3; EN 60950-1; IEC
60950-1
NOTE:
Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and statements.
QuickSpecs
HP ProLiant ML350p Generation 8 (Gen8)
Technical Specifications
DA - 14226 North America — Version 41 — December 9, 2013