Component identification 84
Item
Description
Status
3
DIMM LEDs
Amber = DIMM error
Off = Normal
4
NIC LED
Solid green = Link to network
Flashing green (1 Hz/cycle per sec) =
Network active
Off = No network activity
All other LEDs
Off = Normal
On = Failed
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a
health event. Combinations of illuminated SID LEDs, the system power LED, and the health LED indicate
system status.
Systems Insight
Display LED and
color
Health LED System power
LED
Status
Processor (amber)
Red
Amber
One or more of the following conditions
might exist:
•
Processor in socket
X
has failed.
•
Processor
X
is not installed in the
socket.
•
Processor
X
is unsupported.
•
ROM detects a failed processor during
POST.
Processor (amber)
Amber
Green
Processor in socket
X
is in a pre-failure
condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot
X
is in a pre-failure condition.
Overtemperature (amber) Amber
Green
The Health Driver has detected a cautionary
temperature level.
Overtemperature (amber) Red
Amber
The server has detected a hardware critical
temperature level.
Fan (amber)
Amber
Green
Fan has failed or is missing, but still meets
the minimum fan requirements.
Fan (amber)
Red
Green
Fan has failed or is missing and no longer
meets the minimum fan requirements.
Power supply (amber)
Red
Amber
•
Only one power supply installed and in
standby mode.
•
Power supply fault.
•
System board fault.
Power supply (amber)
Amber
Green
•
Redundant power supply is installed
and only one power supply is functional.
•
AC power cord is not plugged into
redundant power supply.
•
Redundant power supply fault.
•
Power supply mismatch at POST or
through hot-plug addition.
Power cap (off)
—
Amber
Standby
Power cap (green)
—
Flashing green
Waiting for power.
Summary of Contents for ProLiant ML350 Gen9
Page 5: ...Contents 5 Index 123 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 18: ...Illustrated parts catalog 18 ...
Page 64: ...Removal and replacement procedures 64 LFF configuration SFF configuration ...
Page 91: ...Component identification 91 o Rack orientation 24 LFF drives o Tower orientation ...
Page 109: ...Cabling 109 Embedded SATA cabling LFF configuration SFF configuration ...
Page 112: ...Cabling 112 o SFF configuration o LFF configuration SAS Expander cabling One SAS Expander ...
Page 113: ...Cabling 113 o LFF configuration o SFF configuration ...