Removal and replacement procedures 57
c.
Finish the installation by completely tightening the screws in the same sequence.
IMPORTANT:
To avoid a mismatch between boot modes, Hewlett Packard Enterprise
recommends setting system maintenance switch 7 to the same BIOS boot mode the server is
deployed in. Otherwise, the storage controller may not recognize the OS installed on the
storage media.
11.
Install all components removed from the failed system board.
12.
Install the fan cage.
13.
Install the air baffle.
14.
Install the access panel.
15.
Do one of the following:
o
If the server is in a tower configuration, return the server to an upright position.
o
If the server is in a rack configuration, slide the server into the rack.
16.
Connect each power cord to the server.
17.
Connect each power cord to the power source.
18.
Power up the server ("
19.
Do one of the following:
o
For tower models, install the tower bezel.
o
For rack models, install the security bezel.
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access UEFI System Utilities.
2.
Select the
System Configuration
>
BIOS/Platform Configuration (RBSU)
>
Advanced Options
>
Advanced System ROM Options
>
Serial Number
, and then press the
Enter
key.
3.
Enter the serial number and press the
Enter
key. The following message appears:
The serial number should only be modified by qualified service personnel.
This value should always match the serial number located on the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
. The following warning appears:
Summary of Contents for ProLiant ML350 Gen9
Page 5: ...Contents 5 Index 123 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 18: ...Illustrated parts catalog 18 ...
Page 64: ...Removal and replacement procedures 64 LFF configuration SFF configuration ...
Page 91: ...Component identification 91 o Rack orientation 24 LFF drives o Tower orientation ...
Page 109: ...Cabling 109 Embedded SATA cabling LFF configuration SFF configuration ...
Page 112: ...Cabling 112 o SFF configuration o LFF configuration SAS Expander cabling One SAS Expander ...
Page 113: ...Cabling 113 o LFF configuration o SFF configuration ...