Removal and replacement procedures 39
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Remove any attached network cables.
4.
Extend the server from the rack (on page
25
).
5.
Remove the access panel ("
Access panel
" on page
29
).
6.
Remove the primary PCIe riser cage ("
PCIe riser cage (primary)
" on page
31
).
7.
Loosen the thumbscrew.
8.
Remove the existing FlexibleLOM.
Using the blue touchpoint tabs, pull the FlexibleLOM toward the front of the server while removing it, to
avoid catching it on the rear chassis.
To replace the component:
1.
Using the blue touchpoint tabs, firmly seat the FlexibleLOM in the slot, and then tighten the thumbscrew.