![HP ProLiant DL380p User Manual Download Page 20](http://html.mh-extra.com/html/hp/proliant-dl380p/proliant-dl380p_user-manual_164750020.webp)
Component identification 20
Item LED
Status
Definition
3
Do not remove
Solid white
Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, strip size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
PCI riser cage LED
CAUTION:
To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI riser cage.
Status
On = AC power is connected.
Off = AC power is disconnected.
Summary of Contents for ProLiant DL380p
Page 6: ...Contents 6 Acronyms and abbreviations 128 Documentation feedback 131 Index 132 ...
Page 47: ...Hardware options installation 47 14 Install the heatsink 15 Remove the two fan blanks ...
Page 61: ...Hardware options installation 61 o 8 or 16 drive SFF o 8 drive LFF ...
Page 91: ...Cabling 91 LFF hard drive cabling Optical drive cabling ...
Page 92: ...Cabling 92 FBWC cabling 8 or 16 drive SFF 8 drive LFF ...
Page 97: ...Cabling 97 Connect the cable as indicated ...
Page 126: ...Support and other resources 126 ...
Page 127: ...Support and other resources 127 ...