System Unit
Chassis Dimensions
(H x W
x D) Add fan extension kit
(with bezel)
6.96 x 17.638 x 35.236in (17.68 x 44.8 x 89.55cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
220lb (99.8kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 to 140 VAC
180 to 264 VAC
Rated Input Current
7.31A at 115VAC
3.6A at 230VAC
Rated Input Frequency
47 to 63 Hz
Rated Input Power
855W (at 100 VAC),
840.72W (at 200 VAC)
Power Specifications
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-energy-
efficient
Power Supply Output
(per power supply)
Rated Steady-State Power 653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet
Temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per every 1000 ft (1.0°C
per every 304.8 m) above sea level to a maximum
of 10,000 ft (3048 m), no direct sustained
sunlight. Maximum rate of change is 18°F/hr
(10°C/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).
Non-operating
-22° to 140° F (-30° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 82.4°F (28°C)
maximum wet bulb temperature, non-
condensing.
Non-operating
5% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
Altitude
Operating
10,000 ft (3048 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable altitude
change rate is 1500 ft/min (457 m/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
QuickSpecs
HP ProLiant SL230s Generation8 (Gen8)
Technical Specifications
DA - 14231 North America — Version 25 — December 16, 2013