background image

On System Management
Processor

HP iLO (Firmware: HP iLO 4)

NOTE:

 For more information, visit: 

http://www.hp.com/go/ilo

.

Memory Protection

Advanced ECC (multi-bit error protection)

Memory

Type

HP SmartMemory

DDR3 Registered (RDIMM), Unbuffered (UDIMM)

DIMM Slots Available

16 DIMM Slots available

Maximum (RDIMM) (per
server tray)

256GB (16 x16GB) Registered memory configurations

Maximum (UDIMM) (per
server tray)

128GB (16 x 8GB) Unbuffered memory configurations

NOTE:

 HP memory from previous generation servers are not qualified or warranted with this HP ProLiant

Server. HP SmartMemory is required to realize the memory performance improvements and enhanced
functionality listed in this document for Gen8. For additional information, please see the HP SmartMemory
QuickSpecs at: 

http://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html

NOTE: 

RDIMM and UDIMMs are all distinct memory technologies and cannot be mixed within a server. The

majority of ProLiant Gen8 servers support RDIMM, UDIMM.

NOTE:

 HP certified SmartMemory must be used to guarantee full 1600MHz speeds.

NOTE: 

Depending on the memory configuration and processor model, the memory speed may run at

1866MHz, 1600MHz, 1333MHz, or 1066MHz. Please see the Online Memory Configuration Tool at:

www.hp.com/go/ddr3memory-configurator

.

NOTE:

 Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient

Features, see: 

www.hp.com/go/proliant-energy-efficient

.

Network Controller

HP Ethernet 1Gb 2-port 361i Adapter

Expansion Slots

Expansion Slot

#

Technology

Bus Width

*

Connector

Width

Form Factor

Notes

1

PCIe 3.0

x16

x16

Low profile slot

 

*Indicates the number of physical electrical lanes running to the connector.

QuickSpecs

HP ProLiant SL230s Generation8 (Gen8)

Standard Features

DA - 14231   North America — Version 25 — December 16, 2013

Page  4

Summary of Contents for ProLiant DL380p Generation8

Page 1: ...d provides continuous proactive monitoring for over 1600 system parameters with zero impact to application performance NOTE The 1U Open View image below shows two SL230s side by side to denote the left and right trays Each unit is a 1U half width form factor 1U Open View 1U Front View 1 Four 4 SFF 2 5 HDD s or four 4 SSD s or two 2 LFF 3 5 HDD s or four 4 non hot plug hard drives using a Quick Rel...

Page 2: ...Xeon E5 2670 v2 2 5GHz 10 core 25MB 8 0GT s QPI 115W DDR3 1866 HT Turbo2 4 4 4 4 4 4 5 6 7 8 Intel Xeon E5 2660 v2 2 2GHz 10 core 25MB 8 0GT s QPI 95W DDR3 1866 HT Turbo2 4 4 4 4 4 4 5 6 7 8 Intel Xeon E5 2650 v2 2 6GHz 8 core 20MB 8 0GT s QPI 95W DDR3 1866 HT Turbo2 4 4 4 4 5 6 7 8 E5 2600 series Processors Entry Processors NOTE All support up to 1066MHz memory speeds Intel Xeon E5 2609 2 4GHz 4 ...

Page 3: ...of DIMMs installed NOTE Up to 2 processors supported Mixing different processor models is not supported NOTE For the Intel C600 Chipset E5 2600 Series the letter preceding the model number indicates the Product Line E3 E5 E7 2600x 2 number of CPUs in a Node 6 is socket segment designation 00 Processor SKU and x L for low power SKUs Cache Memory One of the following depending on Model 30MB 1x30MB L...

Page 4: ...14225_na 14225_na html NOTE RDIMM and UDIMMs are all distinct memory technologies and cannot be mixed within a server The majority of ProLiant Gen8 servers support RDIMM UDIMM NOTE HP certified SmartMemory must be used to guarantee full 1600MHz speeds NOTE Depending on the memory configuration and processor model the memory speed may run at 1866MHz 1600MHz 1333MHz or 1066MHz Please see the Online ...

Page 5: ...roLiant ROM is used to configure the following Processor and chipset status registers System memory memory map and memory initialization System hardware configuration Integrated PCI devices and optional PCIe cards Customer specific BIOS configuration using the HP ROM Based Setup Utility RBSU NOTE For further information please refer to HP s RBSU ROM based setup utility user guide www hp com suppor...

Page 6: ...ompliant SMBIOS 2 6 1 Server Power Cords One 6 Highline IEC IEC power cord ships standard NOTE HP ProLiant SL servers are primarily connected to PDU s in data center racks so they ship standard with only a PDU power cord 416151 B21 If a user wishes to power a ProLiant SL server using a 110V receptacle NEMA 15 the NEMA power cord must be ordered separately NOTE If customers require a power cord the...

Page 7: ...tput and efficiency rating If non matched power supplies are inserted you will get errors and operation will fail HP CS Platinum power supplies are required when enabling HP s Intelligent Power Discovery IPD solution IPD is the first technology to create an automated energy aware network between IT systems and facilities This allows your company to reclaim millions of dollars in wasted power capac...

Page 8: ...s supporting the complete lifecycle of the server from initial deployment through ongoing management to service alerting and remote support HP iLO Management Engine comes standard on all HP ProLiant Gen8 servers The HP iLO Management Engine portfolio includes HP iLO The HP iLO Integrated Lights Out management processor is the core foundation for the HP iLO Management Engine HP Agentless Management...

Page 9: ... with the web download A single web page provides access to a single download containing both the latest version of HP SUM and the latest SPP Optional smaller subsets with only specific types of servers or specific operating systems are offered to save on download time The HP SUM application provides a straightforward intuitive user interface that guides the user through the steps of discovery ana...

Page 10: ...warranty services are available through HP Care Pack services or customized service agreements Hard drives have either a one year or three year warranty NOTE Server Warranty includes 1 year Parts 1 year Labor 1 year on site support with next business day response Warranty repairs may be accomplished through the use of Customer Self Repair CSR parts These parts fall into two categories 1 Mandatory ...

Page 11: ...r web hosting cloud service providers and High Performance Computing environments This license is a specific subset of iLO Advanced functionality provides fast remote access through Text Console via SSH lower operational cost with Dynamic power capping and faster time to resolution through Email based Alerting and proactive notifications With this newly designed HP iLO Scale Out license HPC custom...

Page 12: ...ored by HP Insight Remote Support With Insight Online s easy navigation you can efficiently track your IT support contracts and device status from anywhere and at anytime www hp com go insightonline Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration customization integration and deployment services for HP servers and storage products Customers can choose how ...

Page 13: ...c Care available for each product group Such support solutions enable customers to optimize technology operations minimize risk and drive better business outcomes with easy to buy easy to use scalable support recommendations for servers storage networking and software All three service recommendations include support services from the broader portfolio of Foundation Care and Proactive Care service...

Page 14: ...uct and cannot be resolved by applying known fixes HP will contact the third party vendor and create a problem incident on your behalf Additional Services Software OS Microsoft Linux SUSE Red Hat VMware Installation Start Up and Software Support Microsoft or Linux or VMware education courses 60 Proactive Select Credits Basic Care Basic Care delivers minimum recommended support service level HP Pro...

Page 15: ...hese items will be covered at the same service level and for the same coverage period as the server unless the maximum supported lifetime and or the maximum usage limitation has been exceeded Coverage of the UPS battery is not included standard warranty terms and conditions apply The defective media retention service feature option applies only to Disk or eligible SSD Flash Drives replaced by HP d...

Page 16: ... None ship standard Optical Drive External support only via USB through the SUV port Power Supply Chassis fans and power supplies sold separately Fans Chassis fans and power supplies sold separately Management HP iLO Management Engine standard Optional HP Insight Control Form Factor 1U half width server tray Warranty Server Warranty includes 1 Year Parts 1 Year Labor 1 Year onsite service HP ProLi...

Page 17: ...th server tray Warranty Server Warranty includes 1 Year Parts 1 Year Labor 1 Year onsite service QuickSpecs HP ProLiant SL230s Generation8 Gen8 Pre configured Models DA 14231 North America Version 25 December 16 2013 Page 17 ...

Page 18: ...ith servers the HP node blank Kit 688928 B21 for left and 688930 B21 for right needs to be ordered for each half width 1U space unpopulated HP Server Nodes HP ProLiant SL230s Gen8 1U Left Half Width Tray Configure to order Server 650047 B21 HP ProLiant SL230s Gen8 1U Right Half Width Tray Configure to order Server 650048 B21 Step 2 Choose Required Node Options only one of the following from each l...

Page 19: ...r Kit 654410 L21 HP SL230s Gen8 Intel Xeon E5 2660 2 2GHz 8 core 20MB 95W FIO Processor Kit 654412 L21 HP SL230s Gen8 Intel Xeon E5 2650 2 0GHz 8 core 20MB 95W FIO Processor Kit 654414 L21 HP SL230s Gen8 Intel Xeon E5 2650L 1 8GHz 8 core 20MB 70W FIO Processor Kit 654432 L21 HP SL230s Gen8 Intel Xeon E5 2637 3 0GHz 2 core 5MB 80W FIO Processor Kit 654430 L21 HP Memory NOTE HP memory from previous ...

Page 20: ...00R DDR3 1600 Registered CAS 11 Memory Kit 672631 B21 Unbuffered with ECC DIMMs UDIMMs NOTE The following memory is supported by the E5 2600 v2 series Processors HP 2GB 1x2GB Single Rank x8 PC3L 12800E DDR3 1600 Unbuffered CAS 11 Low Voltage Memory Kit 713975 B21 HP 2GB 1x2GB Single Rank x8 PC3 14900E DDR3 1866 Unbuffered CAS 13 Memory Kit 708631 B21 HP 4GB 1x4GB Dual Rank x8 PC3L 12800E DDR3 1600...

Page 21: ...nt Energy Efficient Features see www hp com go proliant energy efficient NOTE PC3L is a low voltage memory Step 3 Choose Additional Factory Integratable Options HP Networking Gigabit Ethernet Adapters HP Ethernet 1Gb 4 port 366FLR FIO Adapter 684217 B21 FlexibleLOM Adapters HP FlexFabric 10Gb 2 port 526FLR SFP FIO Adapter 684219 B21 HP FlexFabric 10Gb 2 port 533FLR T FIO Adapter 700760 B21 HP Flex...

Page 22: ...wer Supply Kit 684532 B21 NOTE All support up to 1866MHz DDR3 memory speeds HP SL2x0s Gen8 Intel Xeon E5 2695v2 2 4GHz 12 core 30MB 115W Processor Kit 725944 B21 HP SL2x0s Gen8 Intel Xeon E5 2680v2 2 8GHz 10 core 25MB 115W Processor Kit 725937 B21 HP SL2x0s Gen8 Intel Xeon E5 2670v2 2 5GHz 10 core 25MB 115W Processor Kit 725938 B21 HP SL2x0s Gen8 Intel Xeon E5 2660v2 2 2GHz 10 core 25MB 95W Proces...

Page 23: ...M and UDIMMs are all distinct memory technologies and cannot be mixed within a server The majority of ProLiant Gen8 servers support LRDIMM RDIMM and UDIMMs Registered DIMMs RDIMMs NOTE The following memory is supported by the E5 2600 v2 series Processors HP 4GB 1x4GB Single Rank x4 PC3L 12800R DDR3 1600 Registered CAS 11 Low Voltage Memory Kit 713981 B21 HP 4GB 1x4GB Single Rank x4 PC3 14900R DDR3...

Page 24: ... x8 PC3 14900E DDR3 1866 Unbuffered CAS 13 Memory Kit 708635 B21 Unbuffered with ECC DIMMs UDIMMs NOTE The following memory is supported by the E5 2600 series Processors HP 2GB 1x2GB Single Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669320 B21 HP 2GB 1x2GB Single Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory Kit 647905 B21 HP 4GB 1x4GB Dual Rank x8 PC3 12800E DDR...

Page 25: ...00GB 6G SAS 10K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652564 B21 HP 146GB 6G SAS 15K rpm SFF 2 5 inch SC Enterprise 3yr Warranty Hard Drive 652605 B21 SAS Hot Plug SmartDrive SFF 2 5 inch Midline Drives HP 1TB 6G SAS 7 2K rpm SFF 2 5 inch SC Midline 1yr Warranty Hard Drive 652749 B21 HP 500GB 6G SAS 7 2K rpm SFF 2 5 inch SC Midline 1yr Warranty Hard Drive 652745 B21 SAS Quick Rele...

Page 26: ...Value Solid State Drives HP 600GB 6G SATA Value Endurance SFF 2 5 in SC Enterprise Boot 3yr Wty Solid State Drive 739898 B21 HP 300GB 6G SATA Value Endurance SFF 2 5 in SC Enterprise Boot 3yr Wty Solid State Drive 739888 B21 6G SATA ME Hot Plug SFF 2 5 inch Enterprise Mainstream Solid State Drives HP 800GB 6G SATA Mainstream Endurance SFF 2 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 6...

Page 27: ...B 6G SATA Mainstream Endurance SFF 2 5 in QR Enterprise Mainstream 3yr Wty Solid State Drive 730057 B21 HP 400GB 6G SATA Mainstream Endurance SFF 2 5 in QR Enterprise Mainstream 3yr Wty Solid State Drive 730055 B21 HP 200GB 6G SATA Mainstream Endurance SFF 2 5 in QR Enterprise Mainstream 3yr Wty Solid State Drive 730053 B21 HP 100GB 6G SATA Mainstream Endurance SFF 2 5 in QR Enterprise Mainstream ...

Page 28: ...pter 629138 B21 HP Ethernet 10Gb 2 port 530FLR SFP Adapter 647581 B21 HP FlexFabric 10Gb 2 port 533FLR T Adapter 700759 B21 HP FlexFabric 10Gb 2 port 534FLR SFP Adapter 700751 B21 HP FlexFabric 10Gb 2 port 554FLR SFP Adapter 629142 B21 HP Ethernet 10Gb 2 port 560FLR SFP Adapter 665243 B21 HP Ethernet 10Gb 2 port 561FLR T Adapter 700699 B21 NOTE Please see the QuickSpecs for Technical Specification...

Page 29: ...ptions HP SL230s PCIe x8 CPU v2 Riser Kit NOTE Can only be used with E5 2600v2 processors 737686 B21 QuickSpecs HP ProLiant SL230s Generation8 Gen8 Core Options DA 14231 North America Version 25 December 16 2013 Page 29 ...

Page 30: ...e Out 3yr 24x7 Tech Support and Updates Flex Quantity License BD776A HP Integrated Lights Out Scale Out including 3yr 24x7 Tech Support and Updates Tracking License BD777A HP Integrated Lights Out Scale Out including 1yr 24x7 Tech Support and Updates Flex Qty E LTU BD778AAE HP Integrated Lights Out Scale Out 1yr 24x7 Tech Support and Updates Flex Quantity License BD778A HP Integrated Lights Out Sc...

Page 31: ...i Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673642 B21 HP 785GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673644 B21 HP 1205GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673646 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 13587_na 13587_na html HP PCIe Workload Accelerator Opti...

Page 32: ...ash NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 14227_na 14227_na html Smart Array P222 Controller http h18000 www1 hp com products quickspecs 14229_na 14229_na html Smart Array P421 Controller http h18000 www1 hp com products quickspecs 13200_na 13200_na html Smart Array Advanced Pack http h18000 www1 hp com pr...

Page 33: ...e Power System AF469A NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 14059_na 14059_na html HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 2U L530 Low Voltage NA JP Uninterruptible Power System AF466A HP R T3000 G2 2U L620 High Voltage NA JP Uninterruptible Power System AF467A NOTE Please see the QuickSpecs for additional informa...

Page 34: ... Outlet NA JP Basic Power Distribution Unit H5M60A HP Hardwired 200 240 Volt 36 Outlet WW Basic Power Distribution Unit H5M75A HP 5 7kVA 208 Volt Three Phase 27 Outlet NA JP Dual Voltage Basic Power Distribution Unit H5M63A HP 8 6kVA 208 Volt Three Phase 30 Outlet NA JP Dual Voltage Basic Power Distribution Unit H5M64A HP 8 6kVA 208 Volt Three Phase 30 Outlet NA JP Basic Power Distribution Unit H5...

Page 35: ...ower Distribution Unit D9N59A HP 16 6kVA 400 Volt Three Phase 24 Outlet NA Monitored Power Distribution Unit D9N62A HP 19 9kVA 480 Volt Three Phase 30 Outlet NA Monitored Power Distribution Unit D9N63A HP Environmental Sensor for Remote Monitored PDUs HP Environmental Sensor for Remote Monitored PDUs E2D53A NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products ...

Page 36: ... HP Rack Options HP TFT7600 G2 KVM Console and Monitor TFT7600 G2 HP TFT7600 G2 KVM Console Rackmount Keyboard US Monitor AZ870A HP TFT7600 G2 KVM Console Rackmount Keyboard US TAA Monitor AZ885A NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 13731_na 13731_na html HP USB BFR with PVC Free US Keyboard Mouse Kit 631...

Page 37: ...Mainstream Flash Media Drive Key Kit 737953 B21 HP Enterprise Mainstream Flash Media Kits for Memory Cards HP 8GB microSD Enterprise Mainstream Flash Media Kit 726116 B21 HP 32GB microSD Enterprise Mainstream Flash Media Kit 700139 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 13971_na 13971_na html Other USB ...

Page 38: ...ware Support UR413E HP 4 year Next business day ProLiant s6500 Hardware Support UR406E HP 4 year Next business day with Defective Media Retention ProLiant s6500 Hardware Support UR407E HP 5 year 24x7 24 hour Call to Repair ProLiant s6500 Hardware Support UR429E HP 5 year 24x7 24 hour Call to Repair with Defective Media Retention ProLiant s6500 Hardware Support UR430E HP 5 year 4 hour 13x5 ProLiant...

Page 39: ...lable To maximize performance it is recommended to balance the total memory capacity between all installed processors and to load the channels similarly whenever possible Populate DIMMs from heaviest load quad rank to lightest load single rank within a channel Heaviest load DIMM with most ranks within a channel goes furthest from the processor RDIMMs operating at either 1 35V or 1 5V may be mixed ...

Page 40: ...Dual Rank 2R Quad Rank 4R DIMM Capacity 4GB 4GB 4GB 4GB 8GB 8GB 8GB 8GB 8GB 8GB 8GB 16GB 16GB 16GB 16GB 32GB DIMM Native Speed MHz 1600 1333 1600 1866 1600 1600 1866 1333 1600 1600 1866 1333 1600 1600 1866 1866 Voltage Std LV LV Std Std LV Std LV Std LV Std LV Std LV Std Std SLOTS THAT CAN BE POPULATED 16 slot servers 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 MAXIMUM CAPACITY GB Capacity 64 ...

Page 41: ...2 64 64 128 128 64 64 128 128 POPULATED DIMM SPEED MHz 1 DIMM Per Channel 1333 1600 1600 1866 1333 1600 1333 1600 1600 1866 1600 1866 2 DIMM PEr Channel 1333 1600 1600 1866 1333 1600 1333 1600 1600 1866 1600 1866 Maximum capacity will vary based on individual server platform qualification schedule For HP SmartMemory UDIMM is supported at 2DPC DDR3 1333 Third party memory may only support up to 2DP...

Page 42: ... CAS 11 Low Voltage Memory Kit 713981 B21 HP 4GB 1x4GB Single Rank x4 PC3 14900R DDR3 1866 Registered CAS 13 Memory Kit 708637 B21 HP 8GB 1x8GB Dual Rank x4 PC3L 12800R DDR3 1600 Registered CAS 11 Low Voltage Memory Kit 713983 B21 HP 8GB 1x8GB Single Rank x4 PC3L 12800R DDR3 1600 Registered CAS 11 Low Voltage Memory Kit 731765 B21 HP 8GB 1x8GB Dual Rank x4 PC3 14900R DDR3 1866 Registered CAS 13 Me...

Page 43: ...DIMMs NOTE The following memory is supported by the E5 2600 series Processors HP 2GB 1x2GB Single Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669320 B21 HP 2GB 1x2GB Single Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory Kit 647905 B21 HP 4GB 1x4GB Dual Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669322 B21 HP 4GB 1x4GB Dual Rank x8 PC3L 10600E DDR3 13...

Page 44: ...NOTE PC3L is a low voltage memory QuickSpecs HP ProLiant SL230s Generation8 Gen8 Memory DA 14231 North America Version 25 December 16 2013 Page 44 ...

Page 45: ... two 2 5 hot plug drives can configured in this area Note Hot Plug drives option via the hot plug hard drive kit PN 655618 B21 Drives load into the front bezel via the two PCIe slots QuickSpecs HP ProLiant SL230s Generation8 Gen8 Storage DA 14231 North America Version 25 December 16 2013 Page 45 ...

Page 46: ...r 10 C hr The upper limit may be limited by the type and number of options installed System performance may be reduced if operating with a fan fault or above 86 F 30 C Non operating 22 to 140 F 30 to 60 C Maximum rate of change is 36 F hr 20 C hr Relative Humidity non condensing Operating 10 to 90 relative humidity Rh 82 4 F 28 C maximum wet bulb temperature non condensing Non operating 5 to 95 re...

Page 47: ...Base T IEEE 802 3u 100Base TX IEEE 1588 IEEE 802 1AS IEEE 802 3az Energy Efficient Ethernet EEE Data Transfer Method PCI Express v 2 1 5 0 GT s and 2 5 GT s bus speeds and supports for x1 x2 x4 links widths Lanes Controller I350 Powerville Network Transfer Rate 10Base T Half Duplex 10 Mb s per port 20 Mb s Combined 10Base T Full Duplex 20 Mb s per port 40 Mb S Combined 100Base TX Half Duplex 100 M...

Page 48: ...for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2013 Hewlett Packard Development Company L P The information containe...