Component identification 103
Green LED
Amber LED
Interpretation
Flashing (2 Hz)
Alternating with
amber LED
Flashing (2 Hz)
Alternating with
green LED
One of the following conditions exists:
•
The charging process has timed out.
•
The capacitor pack is not connected.
On
On
The flash code image failed to load.
Off
Off
The flash code is corrupt.
Hot-plug fans
CAUTION:
To avoid damage to server components, fan blanks must be installed in fan bays 5
and 6 in a single-processor configuration.
The only two valid fan configurations are listed in the following table.
Configuration
Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6
1 processor
Fan
Fan
Fan
Fan
Fan blank
Fan blank
2 processors
Fan
Fan
Fan
Fan
Fan
Fan
For a single-processor configuration, four fans and two blanks are required in specific fan bays for
redundancy. A fan failure or missing fan causes all fans to spin at high speed. A second fan failure or missing
fan causes an orderly shutdown of the server.
Installing more than the required number of fans in a single-processor configuration is not a supported
configuration.
For a dual-processor configuration, six fans are required for redundancy. A fan failure or missing fan causes
all fans to spin at high speed. A second fan failure or missing fan causes an orderly shutdown of the server.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server. The server shuts down during the following
temperature-related scenarios:
Summary of Contents for ProLiant DL380 G7
Page 5: ...Contents 5 Index 110 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 16: ...Customer self repair 16 ...
Page 20: ...Illustrated parts catalog 20 System components ...
Page 82: ...Cabling 82 Cabling SAS hard drive cabling Optical drive cabling ...
Page 83: ...Cabling 83 BBWC battery cabling FBWC capacitor pack cabling ...