HP Array Configuration Utility 93
Error code Error message
Comment or clarification
2836
New Logical Drive ID does not match the
next available logical drive ID.
If you are attempting to replicate a
configuration that has non-consecutive
logical drive numbers, then you must
change the script file so that the logical drive
numbers are consecutive.
The script file specifies a logical drive ID that is not
the first unused ID in the sequence. For example, this
message appears if the controller has only Logical
Drive 1 and the script file specifies creation of
Logical Drive 3 (omitting Logical Drive 2). A common
cause of this error is that the input file specifies
nonsequential logical drive numbers. In this case,
change the logical drive numbers in the input file so
that they are sequential.
2837
New Logical Drive ID already exists
This error occurs in Configure mode when the logical
drive ID specified in the script file already exists in
the configuration. In Configure mode, you can
create new logical drives only.
2838
Cannot create Logical Drive
The array has no free space, or the maximum
number of logical drives has been reached already.
2839
Cannot migrate Logical Drive RAID
The controller does not support RAID migration, or
migration is not possible with the current controller
configuration.
2841
Cannot extend Logical Drive
The controller does not support extension, or the
current controller configuration cannot be extended.
For example, extension is not possible if the array
has no free space.
2842
Invalid RAID
The specified RAID level is invalid or is not possible
with the current physical disk and array
configuration.
2843
Invalid Size
The specified size is invalid or is not possible with the
current configuration.
2844
Invalid Stripe Size
The specified stripe size is invalid, not supported by
the current RAID level, or not possible with the
current configuration.
2849
Invalid ClearConfigurationWithDataLoss
parameter
The valid parameters are Yes and No (default).
2850
Controller does not support Chassis Name The controller does not support setting a chassis
name.
2851
Invalid Chassis Name
The entered chassis name is invalid. Use characters
from the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +,
:, ., /, and [space]. The name cannot end with a
space character or exceed the maximum number of
characters allowed by the controller.
2852
Invalid SSP State
The requested SSP state is not a valid SSP state.
2853
Cannot change SSP settings
The SSP settings cannot be changed for the controller
or logical drive.
2854
Invalid SSP Adapter ID
The adapter ID is not a valid adapter ID that was
detected by the controller.
2857
Invalid Surface Scan Delay
—
2861
Controller does not support redundancy
settings
The controller is not redundant or does not support
redundancy settings.
2864
Invalid Preferred Path Mode
The specified value for the preferred path mode is
not valid, or the controller is not available.
2865
Invalid Preferred Path
The specified preferred path is not a valid chassis