background image

HP Basic Power
Distribution Units

HP 1.9kVA 120 Volt 12 Outlet NA/JP Basic Power Distribution Unit

H5M54A

HP 2.8kVA 120 Volt 18 Outlet NA/JP Basic Power Distribution Unit

H5M55A

HP 3.6kVA 200-240 Volt 12 Outlet WW Basic Power Distribution Unit

H5M56A

HP 3.6kVA 200-240 Volt 20 Outlet WW Basic Power Distribution Unit

H5M57A

HP 4.9kVA 208 Volt 20 Outlet NA/JP Basic Power Distribution Unit

H5M58A

HP 4.9kVA 208 Volt 30 Outlet NA/JP Basic Power Distribution Unit

H5M59A

HP 8.3kVA 208 Volt 36 Outlet NA/JP Basic Power Distribution Unit

H5M60A

HP 8.6kVA 208 Volt Three Phase 18 Outlet NA/JP Basic Power Distribution Unit

H5M61A

HP 8.6kVA 208 Volt Three Phase 30 Outlet NA/JP Basic Power Distribution Unit

H5M62A

HP 5.7kVA 208 Volt Three Phase 27 Outlet NA/JP Dual Voltage Basic Power Distribution
Unit

H5M63A

HP 8.6kVA 208 Volt Three Phase 30 Outlet NA/JP Dual Voltage Basic Power Distribution
Unit

H5M64A

HP 11kVA 400 Volt Three Phase 42 Outlet NA Basic Power Distribution Unit

H5M67A

HP 7.3kVA 230 Volt 20 Outlet INTL Basic Power Distribution Unit

H5M68A

HP 7.3kVA 230 Volt 30 Outlet INTL Basic Power Distribution Unit

H5M70A

HP 11kVA 230 Volt 36 Outlet INTL Basic Power Distribution Unit

H5M71A

HP 11kVA 400 Volt Three Phase 30 Outlet INTL Basic Power Distribution Unit

H5M72A

HP 11kVA 400 Volt Three Phase 42 Outlet INTL Basic Power Distribution Unit

H5M73A

HP Hardwired 200-240 Volt 36 Outlet WW Basic Power Distribution Unit

H5M75A

HP 13.2kVA 480 Volt Three Phase 15 Outlet NA Basic Power Distribution Unit

H3X07A

HP 19.9kVA 480 Volt Three Phase 30 Outlet NA Basic Power Distribution Unit

H3X08A

HP 277 Volt options for H3X07A and H3X08A

 

HP 800VA - 277V Input / 230V Output NA Rack Mount Transformer

H3X09A

NOTE:

 Please see the QuickSpecs for Technical Specifications and additional

information:

http://h18000.www1.hp.com/products/quickspecs/14557_div/14557_div.html

(Worldwide)

 

NOTE:

 Additional HP Power Distribution Units are available. For a complete list of all HP

PDUs and additional information please visit: 

www.hp.com/go/rackandpower

.

 

QuickSpecs

HP ProLiant DL360e Generation 8 (Gen8)

Additional Options

DA - 14327   Worldwide — Version 33 — December 16, 2013

Page  40

Summary of Contents for ProLiant DL360e

Page 1: ...x PCIe 3 0 x16 1 x PCIe 2 0 x8 3 Power supply bay 1 Primary Power Supply 4 12 DIMM slots DDR3 Registered RDIMM Load Reduced LRDIMM or Unbuffered UDIMM memory 4 Power supply bay 2 Shown populated Optional 5 Removable hot plug fan modules for easy serviceability 5 Unit ID LED button 6 Optical Disk Drive Bay 6 HP Ethernet 1Gb 4 port 366i Adapter 7 Video connector 7 Serial connector 8 USB Connectors 8...

Page 2: ...0MB 8GT s QPI 70W DDR3 1600 Turbo2 2 2 3 3 4 4 5 5 Turbo NOTE Up to 2 processors supported Performance Energy Star Model configurations include two processors with 8 fans NOTE HT indicates that the processor model supports Intel Hyper Threading Technology NOTE Turbo 2 indicates the maximum potential bin increments when using Intel Turbo Boost Technology with 8 7 6 5 4 3 2 and 1 cores active NOTE D...

Page 3: ...d Reduced LRDIMM Registered RDIMM or Unbuffered UDIMM DIMM Slots Available 12 6 DIMM slots per processor 3 channels per processor 2 DIMMs per channel Standard Entry Models SAS 4GB 1 x 4GB Registered DIMMs PC3L 10600R 1333MHz Standard Entry Models SATA 4GB 1 x 4GB Registered DIMMs PC3L 10600R 1333MHz Standard Base Models 8GB 2 x 4GB Registered DIMMs PC3L 10600R 1333MHz Standard Performance Models 2...

Page 4: ...m ROM HP ROM provides for essential initialization and validation of hardware components before control is passed to the customer installed operating system The ROM also provides the capability of booting from various fixed media HDD CD ROM and removable media USB to continue operation to the operating system HP ROM performs very early configuration of the video controller to allow monitoring of i...

Page 5: ...e bay 4 LFF drive bays total with Optical drive bay NOTE HP ProLiant DL360e Gen8 server offers both SFF and LFF versions in CTO The Optical Drive bay is available with both models NOTE Drive cage changes are not supported NOTE All Pre configured Models come populated with some hard drive blanks installed Should the customer need additional hard drive blanks they can order more using either P N 666...

Page 6: ...ger ship standard with a 12 foot NEMA 5 15P to C13 power cord that connects to 110V US wall outlets in a home or office ProLiant DL servers are primarily connected to power distribution units PDUs in data center racks and now ship standard with a PDU 6 foot C 14 to C13 power cord A0K02A If a user wishes to power a ProLiant DL server using a 110V receptacle NEMA 15 the 6 foot NEMA 5 15 to C13 power...

Page 7: ...to reclaim millions of dollars in wasted power capacity and downtime costs across data centers For more information on HP s Power Discovery Services go to www hp com go ipd It is highly recommended that you use the HP Power Advisor in defining the Right Size power supply for your needs HP Power Advisor can be accessed at www hp com go hppoweradvisor NOTE The 80 PLUS program is a unique forum that ...

Page 8: ... set of embedded management features supporting the complete lifecycle of the server from initial deployment through ongoing management to service alerting and remote support HP iLO Management Engine comes standard on all HP ProLiant Gen8 servers The HP iLO Management Engine portfolio includes HP iLO The HP iLO Integrated Lights Out management processor is the core foundation for the HP iLO Manage...

Page 9: ...th the web download A single web page provides access to a single download containing both the latest version of HP SUM and the latest SPP Optional smaller subsets with only specific types of servers or specific operating systems are offered to save on download time The HP SUM application provides a straightforward intuitive user interface that guides the user through the steps of discovery analys...

Page 10: ...three year warranty refer to the specific hard drive QuickSpecs for details NOTE Server Warranty includes 3 Year Parts 1 Year Labor 1 Year Onsite support with next business day response Warranty repairs may be accomplished through the use of Customer Self Repair CSR parts These parts fall into two categories 1 Mandatory CSR parts are designed for easy replacement A travel and labor charge will res...

Page 11: ... package solely design and priced just right for their IT environments HP iLO Essentials is available on all HP ProLiant Gen8 e series making this an ideal solution for small business owners For more information see http www hp com go iLO essentials HP iLO Advanced HP Integrated Lights Out Advanced License a product option providing smart remote server management without compromise iLO Advanced un...

Page 12: ...ge software Our storage software helps you reduce costs simplify storage infrastructure protect vital assets and respond faster to business opportunities Storage software that gets the job done Data Protection and Recovery Software Whether you re a large enterprise or a smaller business HP data protection and recovery software will cost effectively protect you against disaster and ensure business ...

Page 13: ...oducts Customers can choose how their factory solutions are built tested integrated shipped and deployed Factory Express offers service packages for simple configuration racking installation complex configuration and design services as well as individual factory services such as image loading asset tagging and custom packaging HP products supported through Factory Express include a wide array of s...

Page 14: ...t solutions enable customers to optimize technology operations minimize risk and drive better business outcomes with easy to buy easy to use scalable support recommendations for servers storage networking and software designed to meet your specific needs All three service recommendations include support services from the broader portfolio of Foundation Care and Proactive Care services Optimized Ca...

Page 15: ...ftware 10 Proactive Select Credit package Factory Express http www8 hp com us en business services it services html compURI 1078865 Basic Care Basic Care delivers minimum recommended support service level HP ProLiant Server Hardware Installation Provides for the basic hardware installation of HP branded servers storage devices and networking options to assist you in bringing your new hardware into...

Page 16: ... these items will be covered at the same service level and for the same coverage period as the server unless the maximum supported lifetime and or the maximum usage limitation has been exceeded Coverage of the UPS battery is not included standard warranty terms and conditions apply The defective media retention service feature option applies only to Disk or eligible SSD Flash Drives replaced by HP...

Page 17: ... R Hot Plug 8 SFF 460W PS Entry Server 668813 xx1 Processor s 1 Intel Xeon E5 2403 1 8GHz 4 core 10MB 80W DDR3 1066 Processor Cache Memory 10MB 1x10MB Level 3 Memory 4GB 1 x 4GB Registered DIMMs PC3L 10600R 1333MHz NOTE Memory runs at 1066MHz speed due to processor Network Controller HP Ethernet 1Gb 4 port 366i Adapter Storage Controller HP Dynamic Smart Array B320i Controller NOTE Provides suppor...

Page 18: ...t Plug Non redundant Fans Management HP iLO Management Engine standard Optional HP iLO Essentials or HP Insight Control Form Factor Rack 1U NOTE Includes Rack Mounting Gen8 non telescoping Friction Rail Kit which does not allow for in rack serviceability The HP 1U Gen8 Cable Management Arm is not available when using Friction Rails To assist in the installation of the server into the rack an optio...

Page 19: ...undant Fans Management HP iLO Management Engine standard Optional HP iLO Essentials or HP Insight Control Form Factor Rack 1U NOTE Includes Rack Mounting Gen8 telescoping SFF Ball Bearing Rail Kit which does allow for in rack serviceability Due to the size and weight of the server two people are required to install the server into the rack The HP 1U Gen8 Cable Management Arm is optional To assist ...

Page 20: ...P Insight Control Standard Energy Star Meets Energy Star requirements Form Factor Rack 1U NOTE Includes Rack Mounting Gen8 telescoping SFF Ball Bearing Rail Kit which does allow for in rack serviceability Due to the size and weight of the server two people required to install the server into the rack The HP 1U Gen8 Cable Management Arm is optional To assist in the installation of the server into t...

Page 21: ...e In these two modes the drives are not part of a hardware RAID or a member of a logical drive The Locate Drive status and Do not remove LEDs in the drive carrier are disabled NOTE Power Supply not included choose from Power Options section NOTE HP Smart Array P222 Controller and HP H222 Host Bus Adapter can be selected with only 4LFF models NOTE HP Smart Array P822 Controller and HP H220 Host Bus...

Page 22: ...P DL360e Gen8 Intel Xeon E5 2430L 2 0GHz 6 core 15MB 60W FIO Processor Kit 660670 L21 Eight Core Processors NOTE All support up to 1600MHz DDR3 memory speeds HP DL360e Gen8 Intel Xeon E5 2470 2 3GHz 8 core 20MB 95W FIO Processor Kit 660650 L21 HP DL360e Gen8 Intel Xeon E5 2450 2 1GHz 8 core 20MB 95W FIO Processor Kit 660652 L21 HP DL360e Gen8 Intel Xeon E5 2450L 1 8GHz 8 core 20MB 70W FIO Processo...

Page 23: ...Unbuffered CAS 9 Low Voltage Memory Kit 647905 B21 HP 4GB 1x4GB Dual Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669322 B21 HP 4GB 1x4GB Dual Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory Kit 647907 B21 HP 8GB 1x8GB Dual Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669324 B21 HP 8GB 1x8GB Dual Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage...

Page 24: ...Plug Power Supply Kit NOTE The HP 750W Common Slot 48VDC power supply does not ship with a power cable It has been designed with a terminal block connection allowing for custom design of power cords by the user 636673 B21 NOTE Option Kits for AC power supplies include the power supply and one PDU IEC cable NOTE HP ProLiant servers ship with an IEC IEC power cord used for rack mounting with Power D...

Page 25: ...tallation HP 1U FIO Friction Rail Kit NOTE Kit contains non telescoping friction rails which do not allow for in rack serviceability The HP 1U Gen8 Cable Management Arm is not available when using Friction Rails Caution HP recommends that a minimum of two people is required for all Rack Server installations Please refer to your installation instructions for proper tools and number of people to use...

Page 26: ...essors NOTE All support up to 1600MHz DDR3 memory speeds HP DL360e Gen8 Intel Xeon E5 2470 2 3GHz 8 core 20MB 95W Processor Kit 660650 B21 HP DL360e Gen8 Intel Xeon E5 2450 2 1GHz 8 core 20MB 95W Processor Kit 660652 B21 HP DL360e Gen8 Intel Xeon E5 2450L 1 8GHz 8 core 20MB 70W Processor Kit 660668 B21 NOTE Up to 2 processors supported NOTE HT indicates that the processor model supports Intel Hype...

Page 27: ... x4 PC3 12800R DDR3 1600 Registered CAS 11 Memory Kit 672631 B21 Unbuffered with ECC DIMMs UDIMM for E5 2xxx and E3 1xxx v3 series Processors HP 2GB 1x2GB Single Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669320 B21 HP 2GB 1x2GB Single Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory Kit 647905 B21 HP 4GB 1x4GB Dual Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Mem...

Page 28: ...tDrive SFF 2 5 inch Midline Drives HP 1TB 6G SAS 7 2K rpm SFF 2 5 inch SC Midline 1yr Warranty Hard Drive 652749 B21 HP 500GB 6G SAS 7 2K rpm SFF 2 5 inch SC Midline 1yr Warranty Hard Drive 652745 B21 SAS Hot Plug SmartDrive LFF 3 5 inch Enterprise Drives HP 600GB 6G SAS 15K rpm LFF 3 5 inch SC Enterprise 3yr Warranty Hard Drive 652620 B21 HP 450GB 6G SAS 15K rpm LFF 3 5 inch SC Enterprise 3yr War...

Page 29: ...e Boot 3yr Wty Solid State Drive 739898 B21 HP 300GB 6G SATA Value Endurance SFF 2 5 in SC Enterprise Boot 3yr Wty Solid State Drive 739888 B21 HP 240GB 6G SATA Value Endurance SFF 2 5 in SC Enterprise Value 3yr Wty Solid State Drive 717969 B21 6G SATA Value Endurance Hot Plug LFF 3 5 inch Enterprise Value Solid State Drives HP 800GB 6G SATA Value Endurance LFF 3 5 in SC Enterprise Value 3yr Wty S...

Page 30: ...ise Performance Solid State Drives HP 400GB 6G SAS SLC SFF 2 5 inch SC Enterprise Performance 3yr Warranty Solid State Drive 653082 B21 HP 200GB 6G SAS SLC SFF 2 5 inch SC Enterprise Performance 3yr Warranty Solid State Drive 653078 B21 3G SATA MLC Hot Plug SFF 2 5 inch Enterprise Mainstream Solid State Drives HP 400GB 3G SATA MLC SFF 2 5 inch SC Enterprise Mainstream 3yr Warranty Solid State Driv...

Page 31: ... port 544QSFP Adapter 649281 B21 NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 13078_div 13078_div html HP Power Supplies NOTE Mixing of power supplies in the same server is not supported All power supplies inside a server must be exactly the same model Mixing Gold Platinum and Platinum Plus certified power supplies is not supported NOTE Prio...

Page 32: ...upplies can be found at http h18000 www1 hp com products quickspecs 14209_div 14209_div html HP Cooling Options HP DL360e Gen8 Redundant Fan Kit NOTE The kit contains one fan to be added to a server with one processor installed to make the fans redundant 661530 B21 HP Graphic Options HP DL360 Gen8 Front Video Adapter Kit NOTE Required to enable the front video port 655915 B21 HP Graphic Card Power...

Page 33: ...p without media The HP Insight Control Media Kit can be ordered separately or can be downloaded at http www hp com go insightupdates NOTE For additional license options please see the QuickSpecs at http h18000 www1 hp com products quickspecs 12631_div 12631_div html HP Integrated Lights Out iLO HP Integrated Lights Out iLO Advanced for ProLiant HP iLO Advanced including 1yr 24x7 Technical Support ...

Page 34: ... in order to obtain a license key Customer also will receive a support agreement BD476A HP Insight Cluster Management Utility Media BD477A NOTE For additional license kits please see the QuickSpecs at http h18004 www1 hp com products quickspecs 12612_div 12612_div html HP I O Accelerator Options Second Generation Accelerators HP 365GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673642 B...

Page 35: ...ay P420 1GB FBWC 6Gb 2 ports Int SAS Controller 631670 B21 HP Smart Array P420 2GB FBWC 6Gb 2 ports Int SAS Controller 631671 B21 Smart Array P421 Controller HP Smart Array P421 1GB FBWC 6Gb 2 ports Ext SAS Controller 631673 B21 HP Smart Array P421 2GB FBWC 6Gb 2 ports Ext SAS Controller 631674 B21 Smart Array P822 Controller HP Smart Array P822 2GB FBWC 2 ports Int 4 ports Ext SAS Controller NOTE...

Page 36: ...Bus Adapter NOTE This is a 2 x4 External Port HBA 650931 B21 HP H222 Host Bus Adapter NOTE Supported on LFF models only 650926 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18004 www1 hp com products quickspecs 14336_div 14336_div html HBA 220 http h18004 www1 hp com products quickspecs 14222_div 14222_div html HBA 221 http h18004 www1 hp com prod...

Page 37: ... Cable QK737A HP Premier Flex LC LC Multi mode OM4 2 fiber 5m Cable QK734A HP Tape Backup NOTE For the complete range of tape drives autoloaders libraries and media see http www hp com go tape For hardware and software compatibility of HP tape backup products see http www hp com storage SPOCK and www hp com go ebs NOTE For Internal drives to be connected to DL servers please make sure that you ord...

Page 38: ...re Channel HBAs HP 81B 8Gb 1 port PCIe Fibre Channel Host Bus Adapter AP769B HP 82B 8Gb 2 port PCIe Fibre Channel Host Bus Adapter AP770B Emulex Fibre Channel HBAs HP 81E 8Gb 1 port PCIe Fibre Channel Host Bus Adapter AJ762B HP 82E 8Gb 2 port PCIe Fibre Channel Host Bus Adapter AJ763B HP SN1000E 16Gb 1 port PCIe Fibre Channel Host Bus Adapter QR558A HP SN1000E 16Gb 2 port PCIe Fibre Channel Host B...

Page 39: ...R5KVA 3U L630 High Voltage NA JP Uninterruptible Power System AF460A NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 14109_div 14109_div html Worldwide R7000 Uninterruptible Power System UPS HP R7KVA 4U 50A High Voltage NA JP Uninterruptible Power System AF462A HP R7KVA 4U IEC 32A High Voltage INTL Uninterruptible Power System AF463A NOTE Pleas...

Page 40: ...H5M67A HP 7 3kVA 230 Volt 20 Outlet INTL Basic Power Distribution Unit H5M68A HP 7 3kVA 230 Volt 30 Outlet INTL Basic Power Distribution Unit H5M70A HP 11kVA 230 Volt 36 Outlet INTL Basic Power Distribution Unit H5M71A HP 11kVA 400 Volt Three Phase 30 Outlet INTL Basic Power Distribution Unit H5M72A HP 11kVA 400 Volt Three Phase 42 Outlet INTL Basic Power Distribution Unit H5M73A HP Hardwired 200 ...

Page 41: ... JP Monitored Power Distribution Unit D9N54A HP 11kVA 400 Volt Three Phase 21 Outlet INTL Monitored Power Distribution Unit H5M68A HP 22kVA 400 Volt Three Phase 33 Outlet INTL Monitored Power Distribution Unit D9N56A HP 11kVA 400 Volt Three Phase 33 Outlet INTL Monitored Power Distribution Unit D9N57A HP 14 4kVA 208 Volt Three Phase 24 Outlet NA Monitored Power Distribution Unit D9N58A HP 17 3kVA ...

Page 42: ...ibution Unit AF504A HP 8 3kVA 40A Single Input Single Phase NA JP Monitored Power Distribution Unit AF506A HP 11kVA 16A Single Input Three Phase INTL Monitored Power Distribution Unit AF508A HP 7 3kVA 32A Single Input Single Phase INTL Monitored Power Distribution Unit AF510A HP Monitored Power Distribution Unit Half Rack Version HP 4 9kVA 24A Single Input Single Phase NA JP Monitored Power Distri...

Page 43: ...h PVC Free US Keyboard Mouse Kit 631341 B21 HP USB BFR with PVC Free UK Keyboard Mouse Kit 631344 B21 HP USB BFR with PVC Free FR Keyboard Mouse Kit 631346 B21 HP USB BFR with PVC Free ES Keyboard Mouse Kit 631348 B21 HP USB BFR with PVC Free DE Keyboard Mouse Kit 631358 B21 HP USB BFR with PVC Free JP Keyboard Mouse Kit 631360 B21 HP USB BFR with PVC Free IT Keyboard Mouse Kit 631362 B21 HP USB B...

Page 44: ...oard JP Monitor AZ882A HP TFT7600 G2 KVM Console Rackmount Keyboard RU Monitor AZ883A HP TFT7600 G2 KVM Console Rackmount Keyboard Intl Monitor AZ884A HP TFT7600 G2 KVM Console Rackmount Keyboard US TAA Monitor AZ885A NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 13731_div 13731_div html Worldwide HP Server Consol...

Page 45: ...the rack The HP 1U Gen8 Cable Management Arm is optional To assist in the installation of the server into the rack an optional installation tool is available by contacting your local services representative Caution HP recommends that a minimum of two people is required for all Rack Server installations Please refer to your installation instructions for proper tools and number of people to use for ...

Page 46: ... Technical Account Manager who remotely delivers firmware software revision management proactive scans and incident trend reports Recommended for customers running a virtualized infrastructure and or customers who desire an enhanced call support experience HP 3 year 4 hour 24x7 ProLiant DL360e Proactive Care Service U6D63E HP 3 year 4 hour 24x7 with Defective Media Retention ProLiant DL360e Proact...

Page 47: ...d resource who delivers support planning and brings technical expertise and best practices advices for the customer s environment HP 3 year ISS ProactiveCare Personalized Support U6W98E Installation Services NOTE Reduce the time required to get your system up and running and help minimize disruptions to your business HP Install ProLiant DL360e Service U6E11E HP Startup ProLiant DL360e Service U6E1...

Page 48: ...r server Install DIMMs only if the corresponding processor is installed If only one processor is installed in a two processor system only half of the DIMM slots are available To maximize performance it is recommended to balance the total memory capacity between all installed processors and to load the channels similarly whenever possible When two processors are installed balance the DIMMs across t...

Page 49: ...peed MHz 1333 1600 1600 1333 1333 1600 1333 1333 1333 1333 Voltage LV Std Std LV LV Std LV LV LV LV SLOTS THAT CAN BE POPULATED 12 slot servers 12 12 12 12 12 12 12 12 12 12 MAXIMUM CAPACITY GB 12 slot servers 48 48 96 96 192 192 384 24 48 96 POPULATED DIMM SPEED MHz 1 DIMM Per Channel 1333 1600 1600 1333 1333 1600 1333 1333 1333 1333 2 DIMM Per Channel 1333 1600 1600 1333 1333 1600 1333 1333 1333...

Page 50: ...ng from the front of your server CPU 1 is on right side and CPU 2 is on the left See the population order by alphabetic and numeric progression below CPU 1 IS PROCESSOR ON RIGHT LOOKING FROM FRONT OF SERVER Channel 1 Channel 2 Channel 3 CPU 1 slot 1 2 3 4 5 6 population order A D B E C F In Order 1 4 2 5 3 6 CPU 2 IS PROCESSOR ON LEFT LOOKING FROM FRONT OF SERVER Channel 1 Channel 2 Channel 3 CPU ...

Page 51: ...mory Kit 647901 B21 HP 16GB 1x16GB Dual Rank x4 PC3 12800R DDR3 1600 Registered CAS 11 Memory Kit 672631 B21 Unbuffered with ECC DIMMs UDIMM HP 2GB 1x2GB Single Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memory Kit 669320 B21 HP 2GB 1x2GB Single Rank x8 PC3L 10600E DDR3 1333 Unbuffered CAS 9 Low Voltage Memory Kit 647905 B21 HP 4GB 1x4GB Dual Rank x8 PC3 12800E DDR3 1600 Unbuffered CAS 11 Memo...

Page 52: ...k Enclosure Up to 4 External HP Smart Array P222 512MB FBWC Controller Up to 8 External HP Smart Array P421 1GB FBWC Controller HP Smart Array P421 2GB FBWC Controller D2700 Disk Enclosure Up to 2 External HP Smart Array P222 512MB FBWC Controller Up to 4 External HP Smart Array P421 1GB FBWC Controller HP Smart Array P421 2GB FBWC Controller QuickSpecs HP ProLiant DL360e Generation 8 Gen8 Storage...

Page 53: ... VAC 750 W at 100 to 120 VAC 750 W at 200 to 240 VAC System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 304 8 m 1 8 F per every 1000 ft above sea level to a maximum of 3048 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr 18 F hr The upper limit may be limited by the type and number of options installed Syste...

Page 54: ...ystander LpAm 35 dBA NOTE Values are subject to change without notification and are for reference only NOTE Performance of system options and ancillary equipment will vary depending on the system configuration NOTE Levels presented do not account for non Hewlett Packard installed hardware Emissions Classification EMC FCC Rating Class A Normative Standards CISPR 22 EN55022 EN55024 FCC CFR 47 Pt 15 ...

Page 55: ... rate Up to 6Gb s SATA Serial ATA Connectors 2 internal x4 connectors Server Interface x4 PCIe 2 0 Speed 6Gb s SAS links Cache Memory Zero Memory RAID has no cache memory optional 40 bit 512MB ECC protected Flash Backed Write Cache FBWC Logical Drives Supported Zero Memory Up to 2 logical volumes 6 physical drives Host Memory Addressing 64 bit supporting greater than 4GB server memory space Hot Pl...

Page 56: ...art Array Advanced Pack SAAP 2 0 is no longer required to enable 6 60 Advanced Data Guarding However controller must be in firmware version 4 68 or later RAID 1 0 Striping Mirroring RAID 0 Striping RAID 1 Mirroring HP Ethernet 1Gb 4 port 366i Adapter Network Interface 10Base T 100Base TX 1000Base TX Compatibility IEEE 802 3 10Base T IEEE 802 3ab 1000Base T IEEE 802 3u 100Base TX IEEE 1588 IEEE 802...

Page 57: ...een These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2013 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation Intel is a US registered trademark of Intel Co...

Reviews: