![HP ProLiant DL320 Generation 5p User Manual Download Page 32](http://html.mh-extra.com/html/hp/proliant-dl320-generation-5p/proliant-dl320-generation-5p_user-manual_164689032.webp)
Hardware options installation 32
Hard drive guidelines
When adding hard drives to the server, observe the following general guidelines:
•
The system automatically sets all drive numbers.
•
If only one hard drive is used, install it in the bay with the lowest drive number.
•
Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options
are:
•
The embedded controller supports non-hot-plug SATA hard drives. Drive LEDs are not supported.
•
Optional SATA controllers support hot-plug SATA hard drives and drive LEDs.
•
Optional SAS controllers support hot-plug SAS or SATA hard drives and drive LEDs.
Removing a hard drive blank
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
Remove the component as indicated.
Removing a hard drive
IMPORTANT:
Hot-plug capability and drive LED support are only available when a supported
optional controller is installed in the server.
To remove the component:
1.
Back up all data on the hard drive.
2.
Power down the server (on page