Component identification 55
Front panel LEDs and buttons
Item Description
Status
1
UID button/LED
Blue = Identification is activated.
Flashing blue = System is being remotely managed.
Off = Identification is deactivated.
2
Internal health LED
Green = System health is normal.
Amber = System is degraded. To identify the component in a
degraded state, refer to system board LEDs (on page
59
).
Red = System critical. To identify the component in a critical state,
refer to system board LEDs (on page
59
).
Off = System health is normal (when in standby mode).
3
NIC 1 link/activity LED
Green = Network link exists.
Flashing green = Network link and activity exist.
Off = No link to network exists.
If power is off, view the LEDs on the RJ-45 connector for status by
referring to the rear panel LEDs ("
Rear panel LEDs and buttons
"
on page
57
).
4
NIC 2 link/activity LED
Green = Network link exists.
Flashing green = Network link and activity exist.
Off = No link to network exists.
If power is off, the front panel LED is not active. View the LEDs on
the RJ-45 connector for status by referring to the rear panel LEDs
("
Rear panel LEDs and buttons
" on page
57
).
5
Drive activity LED
Green = Drive activity is normal.
Amber = Drive failure occurred.
Off = No drive activity.
6
Power On/Standby button
and system power LED
Green = System is on.
Amber = System is shut down, but power is still applied.
Off = Power cord is not attached, power supply failure has
occurred, no power supplies are installed, facility power is not
available, or the DC-to-DC converter is not installed.