Removal and replacement procedures 50
IMPORTANT:
Heatsinks for processors 1 and 2 are not interchangeable with the heatsinks for
processors 3 and 4.
8.
Install the heatsink.
IMPORTANT:
Install all components with the same configuration that was used on the failed
system board.
9.
Install the BBWC battery holders.
10.
Install all components removed from the failed system board.
11.
Install the front panel/hard drive cage assembly.
12.
Install all hard drives and hard drive blanks.
13.
14.
Install the server blade ("
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
System Options
menu.
3.
Select
Serial Number
. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
.
7.
Enter the product ID and press the
Enter
key.
8.
Press the
Esc
key to close the menu.
9.
Press the
Esc
key to exit RBSU.
10.
Press the
F10
key to confirm exiting RBSU. The server will automatically reboot.
Summary of Contents for ProLiant BL685c G6
Page 12: ...Customer self repair 12 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 21: ...Illustrated parts catalog 21 ...
Page 46: ...Removal and replacement procedures 46 o Near mezzanine card connector o Near SD card slot ...
Page 62: ...Component identification 62 Processor 2 DIMM slots Processor 3 DIMM slots ...