HP Storage Controllers
NOTE:
NOTE: The P410i is configured with no cache allowing the end user to select what
cache option of the three different options they desire (if cache is desired in the first
place).
NOTE:
The server supports up to a total of two (2) FBWC options including one added to
the P410i
HP integrated Smart Array P410i Controller option
P410i 512MB Flash Backed Write Cache (FBWC) Module Upgrade
534916-B21
P410i 1GB Flash Backed Cache (FBWC) Module Upgrade
534562-B21
HP Smart Array Advanced Pack (SAAP) No Media 1-Server license including 1yr 24x7
Technical Support
516471-B21
NOTE:
The above SAAP license and any above cache option is required to enable Smart
Array Advanced Pack features on the P410i. For more information go to:
http://www.hp.com/go/saap
.
NOTE:
The Smart Array Advanced Pack is hosted on the P410i Smart Array Controller
hardware firmware stack.
HP Expansion Blade
HP BLc PCI Expansion Blade
448018-B21
NOTE:
Ships with one pre-installed PCI-X connect board. Also includes one PCIe connect
board which requires installation.
NOTE:
The HP PCI Express Mezzanine Pass-Thru Card for HP BladeSystem c-Class (P/N
431643-B21) is required to support the HP Expansion Blade with the BL620c G7. Up to
two expansion blades are supported per server (D2200sb, table blades, and/or PCI
Expansion Blade). The PCI Express Mezzanine Pass-Thru Card(s) must be installed in
mezzanine slots 2 and/or 3. Please see the D2200sb QuickSpecs for technical
specifications and additional information at
http://h18000.www1.hp.com/products/quickspecs/12753_div/12753_div.html
.
HP USB and SD Options
HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver)
DC172B
HP USB 04 Standard Keyboard
DT528A#ABA
HP 2GB USB Flash Media Drive Key Kit
NOTE:
HP qualified blank USB key for use with HP ProLiant servers that support the
VMware virtualization environment and other HP value-add software like SmartStart.
HP recommends this industry standard USB flash device for use with VMware ESXi. USB
device must be installed in the internal slot of the ProLiant server for use with VMware
ESXi. Refer to
HP VMware Getting Started Guide
for installation instructions.
608447-B21
HP Security - TPM (Not
NEBS certified)
HP Trusted Platform Module (TPM) Kit
488069-B21
NOTE:
The TPM key is unique to every TPM deployed server and must be retained.
Misplacing or losing the key could result in data loss.
QuickSpecs
HP ProLiant BL620c Generation 7 (G7) Server Blade
Carrier Grade Supplement
Additional Options
DA - 14179 Worldwide — Version 2 — December 28, 2012
Page 22