11. Assign ONLY
MSM765_Int
to port A1, and ONLY
MSM765_LAN
to port A2. Use the space
bar to change values and the arrow keys to move between items. Moving from left to right,
set port A1 to
No
,
Untagged
,
No
. Set port A2 to
No
,
No
,
Untagged
. Ports A1 and A2 should
now look like this:
12. Consider reserving additional ports for connecting access points to the controller LAN port.
For example, you could set ports A3 and A4 to use the same VLAN as the LAN port, VLAN
MSM765_LAN
in this example. You could then connect access points to ports A3 and A4 of
the Ethernet module.
13. Select
Save
when done, and then select
Return to Main Menu
.
Initial controller configuration
Determine switch index of the controller
The starting point for this procedure is the switch CLI prompt that looks like this:
HP Switch 5406zl#
Initial controller configuration