![HP ProCurve 8212zl Series Installation And Getting Started Manual Download Page 112](http://html.mh-extra.com/html/hp/procurve-8212zl-series/procurve-8212zl-series_installation-and-getting-started-manual_165268112.webp)
B-10
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Sw
itc
h Po
rts a
nd Ne
tw
ork
Cabl
es
Straight-Through Twisted-Pair Cable for
1000 Mbps Network Connections
1000Base-T connections require that all four pairs or wires be connected.
Cable Diagram
Figure B-4. Straight-through Cable Diagram for 1000 Mbps Network Connection
N o t e
Pins 1 and 2 on connector “A”
must
be wired as a twisted pair to pins 1 and 2
on connector “B”.
Pins 3 and 6 on connector “A”
must
be wired as a twisted pair to pins 3 and 6
on connector “B”.
Pins 4 and 5 on connector “A”
must
be wired as a twisted pair to pins 4 and 5
on connector “B”.
Pins 7 and 8 on connector “A”
must
be wired as a twisted pair to pins 7 and 8
on connector “B”.
.
Pin Assignments
For 1000Base-T operation, all four pairs of wires are used for both transmit
and receive.