HP ProCurve Switch 2610 Series

2

Features and benefits

Industry-leading warranty

♦ For as long as you own the product, with next-business-day advance replacement (available in most countries). The following hardware products and their related series modules have a one-year
hardware warranty with extensions available: HP ProCurve Routing Switch 9300m series, HP ProCurve Switch 8100fl series, HP ProCurve Network Access Controller 800, and HP ProCurve DCM
Controller. The following hardware mobility products have a one-year hardware warranty with extensions available: HP ProCurve M111 Client Bridge, HP ProCurve MSM3xx-R Access Points, HP
ProCurve MSM7xx Mobility and Access Controllers, HP ProCurve RF Manager IDS/IPS Systems, HP ProCurve MSM Power Supplies, HP ProCurve 1 Port Power Injector, and HP ProCurve CNMS
Appliances. Disk drives in the HP ProCurve ONE Services zl modules have a five year hardware warranty. Standalone software, upgrades, or licenses may have a different warranty duration. For details,
refer to the ProCurve Software License, Warranty, and Support booklet at 

http://www.procurve.com/warranty

.

Connectivity

• 

IEEE 802.3af Power over Ethernet: 

provides up to 15.4 W per

port to IEEE 802.3af compliant PoE powered devices such as IP
phones, wireless access points, and security cameras

• 

Pre-standard PoE support: 

detects and provides power to

pre-standard PoE devices; see list of supported devices in the
product FAQ at www.

ProCurve.com

• 

Gigabit Uplink Connectivity: 

two 10/100/1000BASE-T ports

and two mini-GBIC ports for connectivity such as Gigabit (SX, LX,
LH, 1000BaseT) and 100Base-FX

• 

ProCurve Auto-MDIX: 

automatically adjusts for straight-through

or crossover cables on all 10/100 ports

• 

Jumbo packet support: 

supports up to 9,216 byte frame size to

improve performance of large data transfers

Resiliency and high availability

• 

IEEE 802.3ad Link Aggregation Protocol (LACP) and

ProCurve trunking: 

support up to 24 trunks, each with up to 8

links (ports) per trunk

• 

IEEE 802.1s Multiple Spanning Tree: 

provides high link

availability in multiple VLAN environments by allowing multiple
spanning trees; provides legacy support for IEEE 802.1d and
IEEE 802.1w

• 

Optional redundant power supply: 

provides uninterrupted

power (provided by HP ProCurve 600 RPS/EPS)

Manageability

• 

RMON, XRMON, and sFlow: 

provide advanced monitoring and

reporting capabilities for statistics, history, alarms, and events

• 

Uni-Directional Link Detection (UDLD): 

monitors a link

between two switches and blocks the ports on both ends of the
link if the link goes down at any point between the two devices

• 

Command authorization: 

leverages RADIUS to link a custom

list of CLI commands to individual network administrator's login;
also provides an audit trail

• 

Multiple configuration files: 

allow multiple configuration files to

be stored to flash image

• 

Dual flash images: 

provides independent primary and

secondary operating system files for backup while upgrading

• 

Stacking capability: 

single IP address management for a virtual

stack of up to 16 switches, including the HP ProCurve Switch
2500 Series, 2510 Series, 2600 Series, 2610 Series, 2810 Series,
2900 Series, 3400cl Series, 3500l Series, 4200vl Series, 6108,
6200yl-24G-mGBIC, and 6400cl Series

• 

Friendly port names: 

allow assignment of descriptive names to

ports

• 

Find-Fix-and-Inform: 

finds and fixes common network problems

automatically, then informs administrator

• 

Software updates: 

free downloads from the Web

• 

Troubleshooting: 

ingress/egress port monitoring enables

network problem-solving

Layer 2 switching

• 

VLAN support and tagging: 

supports the IEEE 802.1Q (4,094

VLAN IDs) and 256 VLANs simultaneously

• 

GARP VLAN Registration Protocol: 

allows automatic learning

and dynamic assignment of VLANs

Layer 3 routing

• 

Basic IP routing: 

enables automatic routing to the connected

VLANs and up to 16 static routes--including one default route--in
IP networks

Security

• 

Multiple user authentication methods:

IEEE 802.1X:

 industry-standard method of user authentication

using an IEEE 802.1X supplicant on the client in conjunction with
a RADIUS server

Web-based authentication:

 similar to IEEE 802.1X, provides a

browser-based environment to authenticate clients that do not
support the IEEE 802.1X supplicant

MAC-based authentication:

 client is authenticated with the

RADIUS server based on the client's MAC address

Summary of Contents for ProCurve 2610-12PWR

Page 1: ...ces The HP ProCurve 2610 24 12PWR 2610 24 PWR and 2610 48 PWR are IEEE 802 3af compliant for Power over Ethernet PoE and provide up to 15 4 W for 12 24 and 48 ports The 2610 24 12PWR has 24 10 100 ports and provides 12 ports of PoE All switches include two 10 100 1000Base T ports and two mini GBIC slots for Gigabit uplink connectivity An optional redundant external power supply is also available t...

Page 2: ...nvironments by allowing multiple spanning trees provides legacy support for IEEE 802 1d and IEEE 802 1w Optional redundant power supply provides uninterrupted power provided by HP ProCurve 600 RPS EPS Manageability RMON XRMON and sFlow provide advanced monitoring and reporting capabilities for statistics history alarms and events Uni Directional Link Detection UDLD monitors a link between two swit...

Page 3: ...unwanted file downloads or unauthorized copying of switch configuration file Switch management logon security can require either RADIUS or TACACS authentication for secure switch CLI logon DHCP protection blocks DHCP packets from unauthorized DHCP servers preventing denial of service attacks STP BPDU port protection blocks Bridge Protocol Data Units BPDUs on ports that do not require BPDUs prevent...

Page 4: ... MB MIPS 300 MHz 16 MB flash 128 MB SDRAM packet buffer size 1 MB MIPS 300 MHz 16 MB flash 128 MB SDRAM packet buffer size 1 MB Mounting Mounts in an EIA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only Mounts in an EIA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only Mounts in an EIA standard 19 in t...

Page 5: ...C IEC 61000 4 5 1 kV 2 kV AC IEC 61000 4 5 1 kV 2 kV AC Conducted IEC 61000 4 6 3V IEC 61000 4 6 3V IEC 61000 4 6 3V Power frequency magnetic field IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 8 1A m 50 or 60 Hz IEC 61000 4 8 1A m 50 or 60 Hz Voltage dips and interruptions IEC 61000 4 11 95 reduction 0 5 period 30 reduction 25 periods IEC 61000 4 11 95 reduction 0 5 period 30 reduction 25 periods IE...

Page 6: ... year 24x7 SW phone support software updates UF792E Installation with minimum configuration system based pricing U4826E Installation with HP provided configuration system based pricing U4830E Refer to the HP Web site at www procurve com services for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP ...

Page 7: ...izontal surface mounting only Performance 100 Mb Latency 6 2 µs LIFO 4 1 µs 1000 Mb Latency 4 4 µs LIFO 2 9 µs Throughput up to 13 0 million pps up to 9 5 million pps Routing Switching capacity 17 6 Gbps 12 8 Gbps MAC address table size 8000 entries 8000 entries Environment Operating temperature 32ºF to 122ºF 0ºC to 50ºC 32ºF to 122ºF 0ºC to 50ºC Operating relative humidity 15 to 95 104ºF 40ºC non...

Page 8: ...sing mini GBICs with this product mini GBICs with revision B or later product ends with the letter B or later e g J4858B J4859C are required When using mini GBICs with this product mini GBICs with revision B or later product ends with the letter B or later e g J4858B J4859C are required Services 3 year 4 hour onsite 13x5 coverage for hardware U4683E 3 year 4 hour onsite 24x7 coverage for hardware ...

Page 9: ...ons RFC 2030 Simple Network Time Protocol SNTP v4 RFC 2131 DHCP RFC 3046 DHCP Relay Agent Information Option IP multicast RFC 3376 IGMPv3 MIBs RFC 1213 MIB II RFC 1493 Bridge MIB RFC 2021 RMONv2 MIB RFC 2096 IP Forwarding Table MIB RFC 2613 SMON MIB RFC 2618 RADIUS Client MIB RFC 2665 Ethernet Like MIB RFC 2668 802 3 MAU MIB RFC 2674 802 1p and IEEE 802 1Q Bridge MIB RFC 2737 Entity MIB Version 2 ...

Page 10: ...ply J8169A HP ProCurve Manager 2 3 HP ProCurve Network Immunity Manager 1 0 50 device license J9060A HP ProCurve Network Immunity Manager 1 0 100 device license J9061A HP ProCurve Network Immunity Manager 1 0 unlimited device license J9062A For more information To learn more about HP ProCurve Networking please visit ProCurve com 2008 Hewlett Packard Development Company L P The information containe...