System Unit
Dimensions (HxWxD)
15.14 x 7.27 x 16.36 in
385 x 185 x 416 mm
Weight
16.7 lb (7.58 kg)
Packaging Dimensions
(DxLxW)
19.63 x 24.13 x 10.56 in
498.6 x 613 x 268.2 mm
Shipping Weight
24.77 lb (111.24 kg)
Temperature
Operating
41° to 95° F (5° to 35° C)
Non-operating
–22° to 149° F (–30° to 65° C)
Relative Humidity
Operating
10% to 90% (non-condensing at ambient)
Non-operating
5% to 95% (non-condensing at ambient)
Shock
Operating
35 G, half-sine
Non-operating
30 G, half-sine
Maximum Altitude
(unpressurized)
Operating
10,000 ft (3048 m)
Non-operating
30,000 ft (9144 m)
For accessibility information on HP products, please visit:
http://www.hp.com/accessibility
.
Unit Environment and
Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and
cold, to ensure that unit is operated within the specified operating range.
Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required
airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are
subject to each other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer.
Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must
be provided on the enclosure, and the same operating guidelines listed above will still apply.
Eco-Label Certifications &
declarations
This product has received or is in the process of being certified to the following approvals and may be
labeled with one or more of these marks:
IT ECO declaration
HP Pro 3120, Microtower PC, HP Pro 3125 Microtower PC and HP Pro 3130 Microtower PC
Energy Consumption
115 VAC
230 VAC
100 VAC
Normal Operation
68.637 W
68.393 W
68.763 W
Sleep (Energy Star low
power mode)
2.8911 W
3.0913 W
2.8888 W
Off
1.0867 W
1.2908 W
1.0597 W
Heat Dissipation
*
115 VAC
230 VAC
100 VAC
Normal Operation
235 BTU/hr
234 BTU/hr
235 BTU/hr
Sleep
10 BTU/hr
11 BTU/hr
10 BTU/hr
Off
4 BTU/hr
4 BTU/hr
4 BTU/hr
QuickSpecs
HP Pro 3100 Series Minitower Business PC
System Unit Specifications
DA - 13640 Worldwide QuickSpecs — Version 13 — 12.10.2010
Page 13