1.
Turn off the computer and any external devices, and disconnect the power cords from the power
outlet.
2.
Disconnect the keyboard, monitor, and any other external equipment connected to the computer.
WARNING!
To reduce the risk of personal injury from electrical shock and/or hot surfaces, be
sure to disconnect the power cord from the wall outlet, and allow the internal system
components to cool before touching.
CAUTION:
When the computer is plugged in, the power supply always has voltage applied to
the system board even when the unit is turned off. Failure to disconnect the power cord can
result in damage to the system.
Static electricity can damage the electronic components of the computer or optional equipment.
Before beginning these procedures, ensure that you are discharged of static electricity by briefly
touching a grounded metal object.
3.
Remove the access panel.
CAUTION:
Resetting CMOS will restore the computer to factory defaults and will erase any
customized information including passwords, asset numbers, and special settings.
4.
Locate the header and jumper labeled
CLEAR CMOS
.
NOTE:
Be sure you have disconnected the AC power cord from the wall outlet. The CMOS will
not clear if the power cord is connected.
NOTE:
The CMOS jumper is light green so that it can be easily identified. For assistance
locating the CMOS jumper and other system board components, see the
Illustrated Parts &
Service Map
(IPSM) for that particular system. The IPSM can be downloaded from
http://www.hp.com/support
.
5.
Remove the CMOS jumper from pins 2 and 3 and put the jumper on pins 1 and 2.
6.
Start the computer. This clears CMOS.
7.
Put the jumper back on pins 2 and 3.
8.
Replace the access panel.
9.
Reconnect the external devices.
10.
Plug in the computer and turn on power.
NOTE:
Use Computer Setup to reset any special system setups along with the date and time.