Diagnostics
Table 3-4: POST Error Messages ( Virus Related
continued
Message Displayed
Description
Static Resource Conflict
Two or more Static Devices are trying to use the same resource
space (usually Memory or I/O).
PCI I/O conflict
A PCI adapter generated an I/O resource conflict when configured
by BIOS POST.
PCI ROM conflict
A PCI adapter generated an I/O resource conflict when configured
by BIOS POST.
PCI IRQ conflict
A PCI adapter generated an I/O resource conflict when configured
by BIOS POST.
PCI IRQ routing table error
BIOS POST (DIM code) found a PCI device in the system but was
unable successfully route an IRQ to the device. Usually this error is
caused by an incomplete description of the PCI Interrupt Routing of
the system.
Timer Error
This message indicates an error while programming the count
register of channel 2 of the 8254 timer. This may indicate a problem
with system hardware.
Interrupt Controller-1 error
BIOS POST could not initialize the Master Interrupt Controller. This
may indicate a problem with system hardware.
Interrupt Controller-2 error
BIOS POST could not initialize the Slave Interrupt Controller. This
may indicate a problem with system hardware.
Table 3-5: POST Error Messages
−
CMOS
Message Displayed
Description
CMOS Date/Time Not Set
The CMOS Date and/or Time are invalid. This error can be resolved
by readjusting the system time in the Setup Utility.
CMOS Battery Low
CMOS Battery is low. This message usually indicates that the
CMOS battery needs to be replaced. It could also display when the
user intentionally discharges the CMOS battery.
CMOS Settings Wrong
CMOS settings are invalid. This error can be resolved by using the
Setup Utility.
CMOS Checksum Bad
CMOS contents failed the Checksum check. It indicates that the
CMOS data has been changed by a program other then the BIOS or
that the CMOS is not retaining its data due to malfunction. This error
can typically be resolved by using the Setup Utility.
HP ProLiant ML150 Server Operations and Maintenance Guide
3-5
HP CONFIDENTIAL
Codename: Stone Soup Part Number: 343329-001 Last Saved On: 8/14/03 10:15 AM