Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix A
117
1. Record ID.
2. Severity for E0 messages.
3. Generator id or sensor reporting the event.
4. Text description of events.
5. Sensor number-Sensor Type:Event Type:Data1 fields for type 02 msgs (triplet) event id for E0 msgs.
6. Data2 and Data3 for type 02 msgs (if applicable) or Data type for E0 messages.
7. Timestamp or extended data specific to the event.
Accessing the logs with MP commands
The SEL and FPL data can also be accessed from the MP logs using the MP card
SL
command.
The
v
command (view mode configuration) determines the format of the display:
•
hex mode
•
text mode
•
keyword mode
Hex Mode Example:
0x5E800A7A00E00FD0 0000000000000003
Text Mode Example:
Log Entry 1: 31 Oct 2003 21:34:17
Alert Level 2: Informational
Keyword: Type-02 0a0700 657152
Cooling unit OK
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - Fan 1 (PSU)
Data1: transition to OK
0x203FA2D559020020 FFFF0007110A0300
Log Entry 0: 31 Oct 2003 21:33:21
Alert Level 3: Warning
Keyword: Type-02 0a0701 657153
Cooling unit warning
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - Fan 1 (PSU)
Data1: transition to Non-Critical from OK
0x203FA2D521020010 FFFF0107110A0300
Keyword mode example: