CANCEL
Δ
1cataloged-procedure-for-startup-name
Operands
cataloged-procedure-for-startup-name
Used to specify the name of the cataloged procedure for startup that was specified in the
START
command when Business Continuity Manager Monitor was started.
identification-name
Used to specify the identification name that was specified in the
START
command when Business
Continuity Manager Monitor was started.
Example
To forcibly stop the Business Continuity Manager Monitor instance whose identification name is
YK
, enter the following command:
CANCEL YK
Return codes for Business Continuity Manager Monitor
“Return codes issued when Business Continuity Manager Monitor is stopped” (page 520)
shows the
return codes issued when Business Continuity Manager Monitor stops.
Table 89 Return codes issued when Business Continuity Manager Monitor is stopped
Meaning
Return Code (Decimal Format)
BCM Monitor terminated normally.
0
The child task terminated abnormally.
4
One of the following errors occurred while analyzing the
Business Continuity Manager Monitor parameter files:
8
•
An attempt to access the Business Continuity Manager
Monitor parameter files failed.
•
The settings specified for the Business Continuity
Manager Monitor parameter files are invalid.
•
GETMAIN
failed.
One of the following errors occurred when not analyzing
the Business Continuity Manager Monitor parameter files:
12
•
An error occurred when specifying the initial settings.
•
No profile has been defined in the RACF FACILITY class.
•
Business Continuity Manager Monitor has not started
via
IKJEFT01
.
•
GETMAIN
failed.
BCM Monitor was stopped by a startup action, an action,
or an error action with
EXIT
specified. The return code
specified for
EXIT
will be issued.
Other
Operator commands available in BCM Monitor
Business Continuity Manager Monitor supports the operator commands shown in
“List of functions
of Business Continuity Manager Monitor commands” (page 521)
. By executing these operator
commands, you can change the behavior or check the status of Business Continuity Manager
Monitor while it is running. Operator commands are executed after all the actions Business Continuity
Manager Monitor is currently performing are finished.
520 Automatic operation using BCM Monitor
Summary of Contents for HPE XP P9500
Page 289: ...Using a 2DC Configuration 289 ...
Page 320: ... YKQUERY YKRESYNC FORWARD YKEWAIT GOTO DUPLEX 320 Maintenance and Troubleshooting Operations ...
Page 325: ... YKQUERY YKRESYNC FORWARD YKEWAIT GOTO DUPLEX Using a Delta Resync Configuration 325 ...
Page 418: ... YKQUERY YKMAKE SELECT COND 418 Maintenance and Troubleshooting Operations ...
Page 469: ...Defining a route list 469 ...
Page 490: ...Figure 121 Example of defining an EXCTG To specify an EXCTG ID 490 Using the ISPF panels ...
Page 576: ...576 Troubleshooting ...
Page 588: ...588 Defining Command Devices in Non basic Configurations ...