Failover
1.
From the local site, execute the
YKSUSPND REVERSE
command for the Cnt Ac-S Z copy pair.
•
YKQUERY
•
YKSUSPND REVERSE
•
YKEWAIT GOTO(SUSPEND) NOINVALIDCHECK
If a route list that contains the primary site is specified for the
YKLOAD
command, the
YKQUERY
command and the
YKEWAIT
command may sometimes encounter an I/O error. To avoid an
I/O error, specify a route list that does not contain the primary site.
Operation at the local site can be started before executing the
YKRESYNC DELTAJNL
command. However, the time it takes for the delta resync pairs between the local site and the
remote site to change to the DUPLEX status after execution of the
YKRESYNC DELTAJNL
command increases depending on the amount of update data from the local site.
2.
From the local site, execute the
YKRESYNC DELTAJNL
command for the delta resync pair.
•
YKQUERY
•
YKRESYNC DELTAJNL
•
YKEWAIT GOTO(DUPLEX)