Pools pools-1 DEGRADED
Controller 1 50014380266A0140 OK
# hardware show status 5001438030123680
Name Dev-id Status
----------------------- ---------------------- --------
Drive Cage 5001438030123680 DEGRADED
Disk 5000C50076A2E72F 5000C50076A2E72F OK
Disk 5000C500768723A7 5000C500768723A7 OK
Disk 5000C500768AF62B 5000C500768AF62B OK
Disk 5000C5007689EC7B 5000C5007689EC7B OK
Disk 5000C50076A07ACB 5000C50076A07ACB OK
Disk 5000C5007687823F 5000C5007687823F OK
Disk 5000C50076A033DB 5000C50076A033DB OK
- Drive_Missing_b1000082 MISSING
Disk 5000C50076A0D1DB 5000C50076A0D1DB OK
Disk 5000C5007686F21F 5000C5007686F21F OK
Disk 5000C5007688B5BB 5000C5007688B5BB OK
Disk 5000C5007689C0A3 5000C5007689C0A3 OK
3.
When you reach a faulty component, you can also use the StoreOnce CLI command to
display details and look at the diagnostic message for more information.;
hardware show status <Dev-id> details
NOTE:
In the following example, we have truncated the output to highlight the information
returned for the missing disk.
# hardware show status 5001438030123680 details
Name
------------------------------------------------------------
Drive Cage
Dev-id = 5001438030123680
Status = DEGRADED
message = -
type = driveEnclosure
model = 12G SAS Exp Card
serialNumber = PDNRB0AZT6G0I5
firmwareVersion = -
location = Port: 1I Box: 1
Disk 5000C50076A2E72F
Dev-id = 5000C50076A2E72F
Status = OK
message = -
type = drive
model = MB4000FCWDK
serialNumber = S1Z0AN1R0000K45005X7
firmwareVersion = HPD5
location = Port: 1I Box: 1 Bay: 1
volumeName = LUN 1, LUN_Pool 1_V1
capacity = 4.00 TB
driveType = HDD
rpm = 7200
totalPowerOnHours = 5351
.....
.....
-
Dev-id = Drive_Missing_b1000082
Status = MISSING
message = The drive is missing or has failed.
type = drive
Using the StoreOnce CLI to identify a problem
21