![HP HP E1346A User Manual Download Page 26](http://html.mh-extra.com/html/hp/hp-e1346a/hp-e1346a_user-manual_162653026.webp)
Chapter 3
Using the HP E1346A Multiplexer Module
Using This Chapter
This chapter uses typical examples to show how to use the 48-Channel
Relay Multiplexer Module. Refer to Chapter 4 (Understanding the
48-Channel Multiplexer Module) for more information. This chapter
contains the following sections:
•
Multiplexer Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 25
•
Connecting Channels to Common for Making
Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26
•
Scanning a Range of Switchbox Channels . . . . . . . . . . . . . . Page 29
Multiplexer Commands
Table 3-1. Multiplexer Commands in Chapter 3
Command
Description
ARM:COUN<
number
>
Selects multiple scanning cycles
INIT[:IMM]
Starts scanning process; use the [ROUT:]SCAN command
to select channels for scanning
INIT:CONT 1 |0 |ON |OFF
Enables/disables continuous scanning cycles
[ROUT:]CLOS <
channel_list
>
Closes all channels in channel list
[ROUT:]CLOS?<
channel_list>
Queries mainframe for channel closure
[ROUT:]OPEN<
channel_list
>
Opens all channels in channel list
[ROUT:]SCAN<
channel_list
>
Closes all channels in channel list one at a time; previous
channel opens before next channel closes
[ROUT:]SCAN:MODE RES
Automatically closes the DT Tree Switch for 2-wire ohms
measurements while scanning
NOTE: The commands with brackets ([ ]) are implied and are not shown in this chapter