Server Power Cords
North America
One 6' Highline (IEC-IEC) power cord ships standard
Japan
One 6' Highline (IEC) power cord and one 6' Lowline power cord ship
standard
ROW
One 6' Highline (IEC) power cord ships standard
NOTE:
HP ProLiant DL120 G6 server ship standard worldwide with a C13 to C14 2M Highline
jumper cord. Japanese models also include a 2M Lowline power cord. If customers require a local
power cord, they can check the power cord matrix for the appropriate country specific cord.
Please see the following power cord matrix:
http://www.hp.com/go/powercordmatrix
.
Power Supply
Auto-sensing 400-Watt PFC Power Supply, CE Mark Compliant
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page.
Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions,
requirements, and specifications for UPS and PDU units. Please see the following link:
www.hp.com/products/powercords
.
System Fans
4 dual rotor fans ship standard.
Required Cabling
For required cabling information, refer to the Web site at:
http://h10010.www1.hp.com/wwpc/us/en/sm/WF05a/15351-15351-3328412-241644-241475-
3579703.html
.
Operating Systems and
Virtualization Software
Microsoft Windows Server
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
NOTE:
For more information on HP's Certified and Supported ProLiant Servers for OS and
Virtualization Software and latest listing of software drivers available for your server, please visit
our Support Matrix at:
http://www.hp.com/go/supportos
and our driver download page
http://www.hp.com/support/DL120G6
Rack Airflow
Requirements
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must
allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to
permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack
must be a minimum of 2.75 inches (7 cm).
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack.
This arrangement ensures proper airflow. Using a rack without blanking panels results in improper
cooling that can lead to thermal damage.
NOTE:
For additional information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server.
QuickSpecs
HP ProLiant DL120 Generation 6
Standard Features
DA - 13504 Worldwide QuickSpecs — Version 8 — 8/20/2010
Page 9