Processor

One of the following
depending on Model

Quad-Core Processors

Intel® Xeon® processor HP X3430 (2.40GHz, 95W, 8MB, 1333, Turbo 1/1/2/3)

Intel® Xeon® processor HP X3440 (2.53GHz, 95W, 8MB, 1333, HT, Turbo 1/1/2/3)

NOTE:

 Available through Configure To Order only. See Factory Integration Models section for

more details.

Intel® Xeon® processor HP X3450 (2.67GHz, 95W, 8MB, 1333, HT, Turbo 1/1/4/4)

Intel® Xeon® processor HP X3460 (2.80GHz, 95W, 8MB, 1333, HT, Turbo 1/1/4/5)

NOTE:

 Available through Configure To Order only. See Factory Integration Models section for

more details.

Intel® Xeon® processor HP X3470 (2.93GHz, 95W, 8MB, 1333, HT, Turbo 1/1/4/5)

NOTE:

 Available through Configure To Order only. See Factory Integration Models section for

more details.

NOTE:

 HT indicates that the processor model supports Intel® Hyper-Threading Technology.

NOTE:

 Turbo indicates the maximum potential frequency increment when using Intel® Turbo

Boost Technology, with 4, 3, 2, and 1 cores are active.

NOTE:

 DDR3 speed is the maximum memory speed of the processor. Actual memory speed may

depend on the quantity and type of DIMMs installed.

Dual-Core Processors

Intel® Celeron® processor G1101 (2.26GHz, 73W, 2MB, 1066)

NOTE:

 Available through Configure To Order only. See Factory Integration Models section for

more details.

Intel® Pentium® processor G6950 (2.8GHz, 73W, 3MB, 1066, HT)

Intel® Xeon® processor L3406 (2.28GHz, 30W, 4MB, 1066, HT, Turbo 2/2)

NOTE: 

Available through Configure To Order only. See Factory Integration Models section for

more details.

Intel® Core™ processor i3-530 (2.93GHz, 73W, 4MB, 1333, HT)

NOTE:

 Available through Configure To Order only. See Factory Integration Models section for

more details.

Intel® Core™ processor i3-540 (3.06GHz, 73W, 4MB, 1333, HT)

NOTE:

 Available through Configure To Order only. See Factory Integration Models section for

more details.

Cache Memory

Integrated 1x8MB Level3 Intel® Smart Cache

Chipset

Intel® 3420 Chipset

Memory Protection

ECC

QuickSpecs

HP ProLiant DL120 Generation 6

Standard Features

DA - 13504   Worldwide QuickSpecs — Version 8 — 8/20/2010

Page 3

Summary of Contents for DL120 - ProLiant - G5

Page 1: ...he HP ProLiant DL120 provides two PCI Express slots with an optional 3rd x4 PCI Express slot optional upgrades including HP HBAs and Smart Array Controllers provide support for SAS hard disk drives DL120 G6 HP Lights Out 100i Remote Management provides cost effective remote management from anywhere anytime Plus you get the cost effective solution of a single processor platform with the performance...

Page 2: ...servers Users performing multi server installations involving large numbers of servers may require the following deployment tools SmartStart Scripting Toolkit Automated scalable deployment utility Smart Components a self executable software consisting of driver and firmware With agents and providers ProLiant 100 series servers get environmental monitoring that is similar and consistent to that of ...

Page 3: ...he maximum potential frequency increment when using Intel Turbo Boost Technology with 4 3 2 and 1 cores are active NOTE DDR3 speed is the maximum memory speed of the processor Actual memory speed may depend on the quantity and type of DIMMs installed Dual Core Processors Intel Celeron processor G1101 2 26GHz 73W 2MB 1066 NOTE Available through Configure To Order only See Factory Integration Models...

Page 4: ...ard PCIe G1 X4 x8 0 28 Half height low profile slot 1 Optional PCI X 133MHz 3 3Volt 64 bit N A 0 1 Full length full height slot Default bus assignment in decimal Inserting cards with PCI bridges may alter the actual bus assignment number Slots are enumerated differently based on OS MS OS s enumerate from lowest to highest Device ID by bus starting with the lowest bus Indicates the number of physic...

Page 5: ...atforms usb support html Graphics 64MB shared supports all display resolutions up to 1600 x 1200 16bpp 75Hz Form Factor Rack 1U 1 69 in 4 32 cm 27 56 deep Embedded Manageability HP ProLiant LO100 HP ProLiant Lights Out 100 simplifies server setup control and lights out remote administration of ProLiant 100 Series servers and functions without additional software It can be accessed from any locatio...

Page 6: ...es the customers with higher levels of operational efficiency and highly reliable systems While ProLiant 100 series G6 servers do not support the Insight Foundation Suite for ProLiant they support a key subset of this important suite software tools and utilities which are very suitable for this class of server SIM SMH agents providers and a SmartStart like deployment CD called Easy Set up which gr...

Page 7: ...OS and SW available for Manual Installation are listed on each servers QuickSpecs SmartStart Scripting Toolkit SSSTK The SmartStart Scripting Toolkit is a server deployment product that delivers an unattended automated installation for high volume server deployments The SmartStart Scripting Toolkit includes a set of utilities for configuring and deploying servers in a customized predictable and un...

Page 8: ...ecurity Trusted Platform Module The TPM Trusted Platform Module is a microcontroller chip that can securely store artifacts used to authenticate the server platform These artifacts can include passwords certificates and encryption keys Windows BitLocker Drive Encryption BitLocker is a data protection feature available in Windows Server 2008 BitLocker leverages the enhanced security capabilities of...

Page 9: ...rs for OS and Virtualization Software and latest listing of software drivers available for your server please visit our Support Matrix at http www hp com go supportos and our driver download page http www hp com support DL120G6 Rack Airflow Requirements Rack 10000 G2 series Cabinets The increasing power of new high performance processor technology requires increased cooling efficiency for rack mou...

Page 10: ...ntact HP s Customer Business Center or an Authorized Partner for assistance http www hp com products configurator Service and Support HP Care Pack Services provide total care and support expertise with committed response times designed to meet your IT and business needs HP Care Pack services include coverage for the HP branded hardware options qualified for the server that are purchased at the sam...

Page 11: ... F excluding HP holidays NOTE For a complete listing of service offerings and information visit http www hp com services proliantservices http h20219 www2 hp com services us en warranty carepack servers proliant html QuickSpecs HP ProLiant DL120 Generation 6 Standard Features DA 13504 Worldwide QuickSpecs Version 8 8 20 2010 Page 11 ...

Page 12: ...dded HP NC107i PCI Express Gigabit Server Adapter Storage Controller HP Smart Array B110i SATA RAID Controller RAID 0 1 1 0 Hard Drives None Ships Standard Internal Storage Up to 4 large form factor Hot Plug drives cold pluggable only NOTE Hot Plug support requires HP Smart Array Hot Plug Advance Pack for B110i or Smart Array Controller and HP CA ASSY 38 4 SATA to MINI SAS Kit P N 591475 B21 Optic...

Page 13: ...0i SATA RAID Controller RAID 0 1 1 0 Rack 1U form factor 1 7 in 4 32 cm Fixed mounting rails Step 2 Choose Required Options only one of the following from each list unless otherwise noted HP Processor Quad Core Intel Xeon processor HP X3430 2 40GHz 95W 8MB 1333 Turbo 1 1 2 3 FIO 581869 L21 Intel Xeon processor HP X3440 2 53GHz 95W 8MB 1333 HT Turbo 1 1 2 3 FIO 578471 L21 Intel Xeon processor HP X3...

Page 14: ...Drive 454234 B21 HP 300GB 3G SAS 15K rpm LFF 3 5 inch Non hot Plug Dual Port Enterprise 3yr Warranty Hard Drive 417950 B21 HP 146GB 3G SAS 15K rpm LFF 3 5 inch Non hot Plug Dual Port Enterprise 3yr Warranty Hard Drive 417855 B21 SATA Non Hot Plug LFF 3 5 inch Midline MDL Drives HP 2TB 3G SATA 7 2K rpm LFF 3 5 inch Non hot Plug Midline 1yr Warranty Hard Drive 507774 B21 HP 1TB 3G SATA 7 2K rpm LFF ...

Page 15: ...ns NOTE For additional options please refer to the Core Options and Additional Options section below QuickSpecs HP ProLiant DL120 Generation 6 Configuration Information Factory Integrated Models DA 13504 Worldwide QuickSpecs Version 8 8 20 2010 Page 15 ...

Page 16: ...HP Hard Drives NOTE The components of a storage subsystem e g the drive the HBA controller firmware and the server backplane should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components NOTE Hard drives have either a one year or three year warranty refer to the specific hard drive QuickSpecs for details SAS Hot Plug LFF 3 5...

Page 17: ...pm LFF 3 5 inch Midline 1yr Warranty Hard Drive 454146 B21 HP 500GB 3G SATA 7 2K rpm LFF 3 5 inch Midline 1yr Warranty Hard Drive 458928 B21 SATA Non Hot Plug LFF 3 5 inch Midline MDL Drives HP 2TB 3G SATA 7 2K rpm LFF 3 5 inch Non hot Plug Midline 1yr Warranty Hard Drive 507774 B21 HP 1TB 3G SATA 7 2K rpm LFF 3 5 inch Non hot Plug Midline 1yr Warranty Hard Drive 507772 B21 HP 500GB 3G SATA 7 2K r...

Page 18: ...bit Server Adapter 538696 B21 HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter 458492 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information www hp com go ProLiantNICs HP I O Expansion Options HP 1U PCI X Riser Option Kit NOTE For PCI X Card support only NOTE The PCI X Riser option is available to convert the full length full height PCI Expre...

Page 19: ... the Insight Control QuickSpecs at http h18000 www1 hp com products quickspecs 12631_div 12631_div html HP Security TPM HP Trusted Platform Module Option Kit 488069 B21 HP Storage Controllers SAS Controllers Smart Array P212 Controller HP Smart Array P212 Zero Memory Controller 462828 B21 HP Smart Array P212 256 MB Controller 462834 B21 Smart Array P411 Controller HP Smart Array P411 256 MB Contro...

Page 20: ...able for installation into the server Connection using the HP SC44Ge SAS Host Bus Adapter 416096 B21 recommended Q1587A HP StorageWorks 1U USB Rack Mount Kit with one DAT 320 USB Tape Drive AP835A HP StorageWorks DAT 320 SAS Internal Tape Drive NOTE For installation into 1U SAS Rack Mount Kit AE459B or 3U SAS Rack Mount Kit AG576B No peripheral bay available for installation into the server Connec...

Page 21: ...ve installation into the server 320GB of disk capacity per data cartridge AJ767A HP StorageWorks RDX500 Internal Removable Disk Backup System NOTE For installation into 1U USB Rack Mount Kit A8007A No peripheral bay available for drive installation into the server 500GB of disk capacity per data cartridge AJ934A HP StorageWorks RDX750 Internal Removable Disk Backup System NOTE For installation int...

Page 22: ...A NA JPN 252663 D73 HP Modular Power Distribution Units mPDU High Volt Model 32A 200 240 VAC Int l 252663 B31 HP Modular Power Distribution Units mPDU High Volt Model 16A 200 240 VAC WW NOTE This PDU has a detachable input power cord and allows for adaptability to country specific power requirements 252663 B24 NOTE Please see the following Modular Power Distribution Unit Zero U 1U Modular PDUs Qui...

Page 23: ...garding KVM switches Serial Console servers rack mount monitors keyboards and all related options please see the following URL http www hp com go kvm HP Care Pack Services Hardware Services On site Service 4 Hour On site Service 5 Day x 13 Hour Coverage 3 Years Electronic UJ252E 4 Hour On site Service 7 Day x 24 Hour Coverage 3 Years Electronic UJ253E Hardware Services Next Business Day On Site Se...

Page 24: ... DIMMs that are closest to the processor Memory channel 2 consists of the three 3 DIMMs that are furthest from the processor Different processor CPU has different memory support Do not mix Unbuffered memory UDIMMs with Registered memory RDIMMs It is not required but it is recommended to load the channels similarly if possible Support up to 4 DIMMs 2 DIMMs per channel max 8GB PC3 10600E DDR3 1333 M...

Page 25: ...DR3 1333 Registered CAS 9 Memory Kit 500656 B21 HP 4GB 1x4GB Quad Rank x8 PC3 8500 DDR3 1066 Registered CAS 7 Low Power Memory Kit 500660 B21 NOTE All DDR3 memory option kits consist of one DIMM per kit For detailed memory configuration rules and guidelines please use the Online DDR3 Memory Configuration Tool www hp com go ddr3memory configurator NOTE Kits described as LP include Low Power DIMMs F...

Page 26: ...prise ENT Drives Quantity Supported Position Supported Controller 600GB 6G SAS 15K DP 450GB 6G SAS 15K DP 450GB 3G SAS 15K DP 300GB 6G SAS 15K DP 300GB 3G SAS 15K DP 146GB 3G SAS 15K DP Up to 4 1 4 HP Smart Array P212 Controller NOTE Support for transfer rates up to 3 Gb s SAS Hot Plug LFF 3 5 inch Midline MDL Drives Quantity Supported Position Supported Controller 1TB 3G SAS 7 2K DP 750GB 3G SAS ...

Page 27: ...antity Supported Position Supported Controller 250GB 1 5G SATA 7 2K 160GB 1 5G SATA 7 2K Up to 4 1 4 HP Smart Array B110i SATA RAID Controller RAID 0 1 1 0 NOTE Transfer rate 3Gb s SATA Maximum Storage Capacity SAS drives Internal 8 0TB 4 x 2TB SAS External 28 0TB 1 x 14 x 2TB SAS Total 36 0TB Maximum Storage Capacity SATA Drives Internal 8 0TB 4 x 2TB SATA External 24 0TB 1 x 12 x 2TGB SATA Total...

Page 28: ...he full compatibility information at http www hp com go connect 462828 B21 HP StorageWorks SCSI Tape Autoloaders DAT 72x10 Autoloader 1 8 G2 Autoloader External HP SC11Xe Host Bus Adapter Please check the full compatibility information at http www hp com go connect 412911 B21 HP StorageWorks SCSI Tape Libraries MSL2024 MSL4048 MSL8096 MSL6000 External HP U320e SCSI Dual Channel Controller Please c...

Page 29: ...DX500 RDX750 External USB 2 0 port N A HP StorageWorks D2D Backup Systems iSCSI D2D2500i D2D4000i External Embedded Network Controller If the server requires a hardware iSCSI initiator the QLogic QLA4050 Host Bus Adapter is recommended HP StorageWorks D2D Backup Systems Fibre Channel D2D4000fc External Direct server attach is not supported requires connection via SAN fabric See http www hp com go ...

Page 30: ...30 W at 100 VAC 430 W at 200 VAC System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above sea level to a maximum of 3050 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr 18 F hr The upper limit may be limited by the type and number of options installed System performance may be r...

Page 31: ...ts is eligible to bear the appropriate compliance logos and statements Power Supply Input voltage specifications Rated input voltage 100 VAC to 240 VAC Input Specifications Rated input line 90 VAC to 264VAC Frequency range 47 to 63 Hz Rated input power 115V input Rated input power 500W assume output wattage 400W 230V input Rated input power 500W assume output wattage 400W Rated input current 6 A 3...

Page 32: ... implement integrated SATA RAID with Smart Start 7 90 on Windows 2000 2003 the use of a floppy drive is necessary Linux Red Hat SuSE UnitedLinux Embedded HP NC107i PCIe Gigabit Server Adapter Network Interface 10Base T 100Base TX 1000Base TX Combines a triple speed IEEE 802 3TM Compliant Media Access Controller MAC with a triple speed Ethernet transceiver Compatibility IEEE 802 3 10Base T IEEE 802...

Page 33: ...ner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell...

Reviews: