Diagnostic Tools
4-31
Error Codes
Microprocessor
Table 4-13
Microprocessor Test Error Codes
Error Code
Description
Recommended Action
101-xx
CPU test failed.
Replace the system board and
retest.
102-xx
Coprocessor error.
Run Computer Checkup or
Computer Setup and retest.
Replace the processor and retest.
103-xx
DMA controller failed.
Replace the system board and
retest.
104-xx
Interrupt controller failed.
Replace the system board and
retest.
105-xx
Port error.
Replace the system board and
retest.
106-xx
Keyboard controller self-test
failed.
Replace the system board and
retest.
107-xx
CMOS RAM test failed.
The following steps apply to error
codes 107-xx through 109-xx:
108-xx
CMOS interrupt test failed.
1.
Replace the battery/clock
module and retest.
109-xx
CMOS clock test failed.
2.
Replace the system board
and retest.
110-xx
Programmable timer test failed.
Replace the system board and
retest.
113-01
Protected mode test failed.
Replace the system board and
retest.
114-01
Speaker test failed.
1.
Verify that the speaker is
connected.
2.
Replace the system board
and retest.
199-xx
Installed devices test failed.
1.
Check system configuration.
2.
Verify cable connections.
3.
Check switch settings.
4.
Run the Diagnostics utility.
5.
Replace the system board
and retest.