• Primary and secondary DNS addresses
• Hostnames and fully qualified hostnames
• HANA instance identifiers (HID), each HANA instance needs a unique HID
CS500 Scale-up networking
Hewlett Packard Enterprise collects a set of parameters for each customer installation with a few details
about setup requirements. One of the requirements is to collect networking details such as addresses and
the type and quantity of networks required for a specific customer implementation.
Seven external networks may connect to the appliance, as shown in Figure 3.
Figure 3
- HANA appliance network customer touch points
All data and BI-connections are 10GbE or 1GbE capable and management connections are 1GbE
capable. These selections help isolate the traffic types onto their own LANs or VLANs as best fits the
customer environment. Management and iLO networks may be merged depending on the data center
requirements. These connections are typically setup at the Hewlett Packard Enterprise factory prior to
delivery of the appliance or can be configured at installation time.
Hewlett Packard Enterprise provides bonding across network cards to protect the connectivity in the case
of a port or a card failure. The ConvergedSystem 500 for SAP HANA Single System Scale-up consists of
two network architectures depending on the size of the appliance. The 128GB, 256GB, 384GB, 512GB,
768GB, 1TB, and 1.5TB share the same network architecture layout as shown in Figure 4. The 2TB, 3TB
and 4TB appliances share the same network architecture layout as shown in Figure 5.
Figure 4
- HPE ConvergedSystem 500 (2 socket) - 128GB/256GB/384GB/512GB/768GB/1TB/1.5TB
appliance network sample network layout
10
Introduction