Removal and replacement procedures 60
8.
Close and lock the heatsink retaining latches.
9.
Install the air baffle ("
Air baffle
" on page
42
).
10.
Install the PCI riser cage.
11.
Install the access panel ("
Access panel
" on page
30
).
12.
Install the server into the rack.
13.
Power up the server.
DIMMs
IMPORTANT:
This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
these two types causes the server to halt during BIOS initialization.
To identify the DIMMs installed in the server, see "DIMM identification (on page
84
)."
To remove the component:
1.
Power down the server (on page
25
).
2.
Extend or remove the server from the rack ("
Remove the server from the rack
" on page
27
, "
Extend
the server from the rack
" on page
26
).
3.
Remove the access panel ("
Access panel
" on page
30
).
4.
Remove the PCI riser cage ("
PCI riser cage
" on page
41
).
5.
Remove the air baffle ("
Air baffle
" on page
42
).