Removal and replacement procedures 50
5.
Power up the recovery server. A 1759 POST message is displayed, stating that valid data was
flushed from the cache. This data is now stored on the drives in the recovery server. You can now
transfer the drives (and controller, if one was used) to another server.
Expansion boards
Half-length expansion board
To remove the component:
1.
Power down the server (on page
25
).
2.
Extend the server from the rack (on page
26
).
3.
Remove the access panel ("
Access panel
" on page
30
).
4.
Disconnect any external cables that are connected to the expansion board.
5.
Remove the PCI riser cage ("
PCI riser cage
" on page
41
).
6.
Disconnect any internal cables that are connected to the expansion board.
7.
Remove the expansion board.
To replace the component, reverse the removal procedure.
Full-length expansion board
To remove the component:
1.
Power down the server (on page
25
).
2.
Extend the server from the rack (on page
26
).
3.
Remove the access panel ("
Access panel
" on page
30
).
4.
Disconnect any external cables that are connected to the expansion board.
5.
Remove the PCI riser cage ("
PCI riser cage
" on page
41
).
6.
Disconnect any internal cables that are connected to the expansion board.
Summary of Contents for AX691B
Page 12: ...Customer self repair 12 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 68: ...Cabling 68 Cabling SAS hard drive cabling Optical drive cabling ...