Hardware specifications

Switch Chassis

Size (WxDxH)

442.5 x 473 x 43.95 mm (17.42x 18.62 x 1.73 

inches)

Weight

8.95 kg (19.73 lb), with two installed PSUs

Temperature

Operating: 0°C to 40°C (32°F to 104°F)

Storage: -40°C to 70°C (-40°F to 158°F)

Humidity

Operating: 5% to 95% (non-condensing)

Operating 

Altitude

Up to 3000 m (10,000 ft)

Acoustics

Noise Emission LpA=61.1 dB at virtual 

workspace according to DIN 45635 T.19

Power 

Consumption

282 Watts maximum

AC PSU

Power AC Input 

Rating

100–240 VAC, 50-60 Hz, 400 Watts, hot 

pluggable

System AC 

Input Rating

100–240 VAC, 50-60 Hz, 6–3 A

Power DC 

Output Rating

5 VDC @ 3 A

12 VDC @ 33 A

Regulatory Compliances

Emissions

EN 55022:2010, Class A

EN 61000-3-2:2014, Class A

EN 61000-3-3:2013

FCC Class A

VCCI Class A

CE Mark

Immunity

EN 55024:2010

IEC 61000-4-2/3/4/5/6/8/11

Safety

UL 60950-1/CSA C22 2 No. 60950-1

EN/IEC 60950-1

EN60850-1/IEC 60825-1

Installation precautions

Warnings

The rack or cabinet should be adequately secured to 

prevent it from becoming unstable, tilting, or falling.

Devices installed in a rack or cabinet should be mounted 

as low as possible, with the heaviest devices at the bottom 

and progressively lighter devices above.

Cautions

Ensure the power source circuits are properly grounded, 

then use the power cord supplied with the switch to 

connect to the AC power source.

If your installation requires a different power cord than the 

one supplied with the switch and/or power supply, be sure 

the cord is adequately sized for the switch’s current 

requirements. In addition, be sure to use a power cord 

displaying the mark of the safety agency that defines the 

regulations for power cords in your country/region. The 

mark is your assurance that the power cord can be used 

safely with the switch and power supply.

When installing the switch, the AC outlet should be near 

the switch and should be easily accessible in case the 

switch must be powered off.

Ensure the switch does not overload the power circuits, 

wiring, and over-current protection. To determine the 

possibility of overloading the supply circuits, add together 

the ampere ratings of all devices installed on the same 

circuit as the switch and compare the total with the rating 

limit for the circuit. The maximum ampere ratings are 

usually printed on the devices near the AC power 

connectors.

Do not install the switch in an environment where the 

operating ambient temperature exceeds its specification.

Ensure the airflow around the switch is not restricted. 

Leave at least 7.6 cm (3 inches) for cooling. 

For additional safety and regulatory information, and switch 

recycling information, refer to the safety and regulatory 

documentation on the Hewlett Packard Enterprise website at 

www.hpe.com/support/Safety-Compliance-EnterpriseProducts

Power cords

Argentina

Australia/New Zealand

Brazil

Chile

China

Continental Europe

Denmark

India

Israel

Japan

Malaysia

Switzerland

South Africa

South Korea

Taiwan

Thailand

United Kingdom/Hong Kong/Singapore

United States/Canada/Mexico

8121-0729

8121-0837

8121-1071

8121-0735

8121-0943

8121-0731

8121-0733

8121-0564

8121-1004

8121-1143

8121-0739

8121-0738

8121-0737

8121-0731

8121-0964

8121-0734

8121-0739

8121-1141

WARNING

FOR INDOOR USE ONLY.  The switch, AC power cord, 

and all connected cables are not designed for outdoor 

use.

Summary of Contents for Altoline 6921

Page 1: ...flow direction That is all modules must have a front to back F2B airflow direction or all modules must have a back to front B2F airflow direction The airflow direction of fan trays is indicated by text printed on the modules 1 Attach the brackets to the switch 2 Use the screws supplied with the rack to secure the switch in the rack CAUTION Installing the switch in a rack requires two people One pe...

Page 2: ...hing airflow direction as the installed fan tray 2 Connect an external AC power source to the modules 1 Verify basic switch operation by checking the system LEDs When operating normally the PSU1 PSU2 Diag and Fan LEDs should all be on green NOTE Refer to the network operating system NOS installer and NOS documentation for details on software options and set up for ONIE 1 2 1 1 For the RJ 45 Manage...

Page 3: ...a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country region The mark is your assurance that the power cord can be used safely with the switch and power supply When installing the switch the AC outlet should be near the switch and should be easily accessible in case the switch must be powered off Ensure the switch does not overload the p...

Page 4: ... such source code on CD DVD please send a check or money order in the amount of US 10 00 to Hewlett Packard Enterprise Attn HPN Open Source Query M S 5554 8000 Foothills Blvd Roseville CA 95747 USA Please specify the product and version for which you are requesting source code You may also request a copy of this source code by contacting the HPN Open Source Query Team via email at HPN Open Source ...

Reviews: