168
[SwitchE-pim] c-bsr vlan-interface 102 32 20
[SwitchE-pim] c-rp vlan-interface 102 group-policy 2005
[SwitchE-pim] quit
4.
Verify the configuration.
Carry out the
display pim interface
command to view the PIM configuration and running status on each
interface. For example:
# View the PIM configuration information on Switch A.
[SwitchA] display pim interface
VPN-Instance: public net
Interface NbrCnt HelloInt DR-Pri DR-Address
Vlan100 0 30 1 10.110.1.1 (local)
Vlan101 1 30 1 192.168.1.2
Vlan102 1 30 1 192.168.9.2
To view the BSR election information and the locally configured C-RP information in effect on a switch,
use the
display pim bsr-info
command. For example:
# View the BSR information and the locally configured C-RP information in effect on Switch A.
[SwitchA] display pim bsr-info
VPN-Instance: public net
Elected BSR Address: 192.168.9.2
Priority: 20
Hash mask length: 32
State: Accept Preferred
Scope: Not scoped
Uptime: 00:40:40
Expires: 00:01:42
# View the BSR information and the locally configured C-RP information in effect on Switch D.
[SwitchD] display pim bsr-info
VPN-Instance: public net
Elected BSR Address: 192.168.9.2
Priority: 20
Hash mask length: 32
State: Accept Preferred
Scope: Not scoped
Uptime: 00:05:26
Expires: 00:01:45
Candidate BSR Address: 192.168.4.2
Priority: 10
Hash mask length: 32
State: Candidate
Scope: Not scoped
Candidate RP: 192.168.4.2(Vlan-interface105)
Priority: 192
HoldTime: 150
Advertisement Interval: 60
Next advertisement scheduled at: 00:00:34
Summary of Contents for A5500 EI Switch Series