Troubleshooting
Firmware Selftest Failures
4-9
Table 4-1 provides information on interpreting the system status from the LEDs.
Table 4-1 LED Indicators
SYSFAIL
(Red)
POWER
(Green)
Meaning
Possible Solution
Off
Off
No Power
Check for board seating in
chassis.
On
2Hz Flash
Normal Power-on/
selftest
If the system never proceeds
past this point, either the con-
sole path is not set or there is
a critical CPU failure.
Refer to “Using the Emer-
gency Interactive Console
Search” in Chapter 3 to set the
console path. If this fails,
replace the system board.
On
Off
Memory Failure
Troubleshoot for failed RAM
card or problem with the
RAM connection.
On
1 Flash/
second
CPU (board) Failure
Replace the system board.
On
4 Flash/
second
No console identified
Check the console search path
and keyboard connections. If
no problem is found, replace
the system board.
On
On
OS is booted with
VME services failure
Check the Operating System
VME services. Check that
VME services is configured in
the kernel.
Off
On
OS is booted with
VME services OK