Error
Messages
The
error
codes
generated
by
the
HP
70310A
Precision
Frequency
Reference
are
listed
below
in
numerical
order
.
Types
Numbers
Usage/Operating
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2000
to
2999
Hardware
W
arning
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6000
to
6999
Hardware
Broken
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7000
to
7999
Usage/Operating
Errors
These
errors
occur
when
the
instrument
is
used
incorrectly
.
2001
illegal
cmd
|
This
is
a
user-generated
system
protocol
error
.
2002
illegal
parameter
|
This
is
a
user-generated
system
protocol
error
.
2006
Param
out
of
range
|
This
is
a
user-generated
system
protocol
error
.
2009
Protocol
error
|
This
is
a
user-generated
system
protocol
error
.
2027
Service
mode
--
do
IP/(For
service
only)
|
This
is
a
user-generated
system
protocol
error
.
The
bandwidth
or
Reference
Select
are
not
in
their
A
UTO
modes
.
Hardware
W
arning
Errors
These
error
codes
report
the
status
of
the
HP
70310A
hardware
or
indicate
that
some
of
the
hardware
may
be
broken.
These
error
codes
indicate
that
measurement
accuracy
may
be
impaired.
6000
EAROM
unprotected
|
The
write-protect
switch
on
the
A2
P
ower
Supply/Processor
board
assembly
is
set
to
the
write
position.
The
correct
setting
is
silk-screened
on
the
left
side-cover
of
the
module
.
6014
PLL
error
|
Either
a
hardware
failure
exists
,
or
the
frequency
reference
source
(internal
or
external)
is
not
close
enough
to
1,
2,
5,
or
10
MHz
for
the
module
to
operate
.
6015
Oven
cold
|
The
A6
Oven/Oscillator
assembly
has
not
reached
normal
operating
temperature
of
approximately
85
C,
and
there
is
no
external
reference
applied.
If
the
error
appears
at
power-up
when
the
instrument
has
been
o
for
more
than
fteen
minutes
and
then
disappears
after
the
instrument
has
been
on
for
fteen
to
twenty
minutes
,
the
most
probable
causes
are:
(a)
the
external
power
pack
has
an
open
fuse
,
(b)
the
external
power
pack
is
not
properly
connected,
(c)
external
power
pack
is
faulty
,
or
(d)
the
HP
70310A
module
has
faulty
hardware
.
Note
At
ambient
temperatures
below
the
specied
operating
range
of
the
module
,
the
oven
may
not
be
able
to
generate
enough
power
to
keep
itself
at
approximately
85
C.
6016
No
Freq
Reference
|
No
external
frequency
reference
is
applied
and
no
internal
oven/oscillator
is
present.
5-2
T
roubleshooting
Summary of Contents for 70310A
Page 6: ......
Page 14: ...Figure 1 2 HP 70310A Module with Accessories 1 4 General Information ...
Page 30: ...Figure 2 3 External Power Pack Installation 2 4 Installation ...
Page 64: ......
Page 66: ......