background image

 

Specifications  10 

Specifications 

Cable specifications 

 

SFP+ 
module type 

Cable 
Connector 

Type 

Wavelength 
(nm), type of 

cable 

Core Size 
(microns, 

µm) 

Cable grade  Minimum 

modal 

bandwidth 

(MHz-km) 

Maximum 
Cable Length 

(meters) 

10GBASE-SR 
(short range) 

Optical 
Module 

LC 

850, 
Multi-Mode 

Fiber (MMF) 

62.5 
62.5 

50 

50 
50 

(“FDDI”) 
OM1 

 

OM2 
OM3 

160 
200 

400 

500 
2000 

26 
33 

66 

82 
300 

10GBASE-CR 

with Direct 
Attached 

Copper 

(DAC) cable 

SFP+ 

N/A, Twin 

Axial Copper 

24 to 28 

AWG, 

depending on 
length and 

manufacturer  

N/A 

N/A 

 

 

General specifications 

    

Specification 

Value 

Controller 

Intel 82599 (Niantic) 

Data rate 

10 Gb/s per port, 20 Gb/s combined, full-duplex 

PCI bus 

PCI Express x8 Gen3 

Connectors 

Two 10 Gb SFP+ 

Dimensions (LxW) 

13.21 cm x 6.89 cm (5.2 inches x 2.7 inches) without bracket 

 

 

Compliance 

    

Compliance 

Standard 

IEEE 

IEEE802.3, IEEE802.3ap, IEEE802.3xx, IEEE802.2x, IEEE802.3ad, 802.1Qaz, 

802.1Qau, 802.1Qbb, 802.1Qbg, 802.1Qbh 

Safety 

UL Mark (US and Canada) 

EN 60950 

Summary of Contents for 697497-001

Page 1: ...is for the person who installs administers and troubleshoots servers and storage systems HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Part Number 697497 001 May 2012 Edition 1 ...

Page 2: ... products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Microsoft and Windows are U S registered trademarks of Microsoft Corporation Intel is a trademark of Intel Corporation in the United States and other countries Bluetooth is a trademark owned by its proprietor and use...

Page 3: ...ications 10 Compliance 10 Power and environmental specifications 11 Regulatory compliance notices 12 Regulatory compliance identification numbers 12 Federal Communications Commission Notice 12 Modifications 12 European Union regulatory notice 12 Canadian notice Avis Canadien 13 Korean class B notice 13 Japanese class B notice 13 Disposal of waste equipment by users in private households in the Eur...

Page 4: ... damage to the equipment Do not disable the power cord grounding plug The grounding plug is an important safety feature Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times Unplug the power cord from the power supply to disconnect power to the equipment Do not route the power cord where it can be walked on or pinched by items placed against it Pay pa...

Page 5: ...ion see the Contact HP website http www hp com go assistance In the United States To contact HP by phone call 1 800 334 5144 For continuous quality improvement calls may be recorded or monitored If you have purchased a Care Pack service upgrade see the Support Drivers website http www8 hp com us en support drivers html If the problem cannot be resolved at the website call 1 800 633 3600 For more i...

Page 6: ...owing illustration with SFP ports and LEDs The HP Ethernet 10Gb 2 port 560SFP Adapter LEDs operate as described in the following table Item LED Status Description 1 Link Off No link to the adapter is established The adapter is not receiving power or the cable connection is faulty On Amber Link to the adapter is established at 10 Gb s The adapter is receiving power and the cable connection is good ...

Page 7: ...is intended to be installed in Certified UL or CSA ITE equipment having instructions for adding and removing user installed components such as PCI PCI X and PCI Express devices Refer to the equipment instructions to verify that it is suitable for user installed components and that it has the power capacity to support all of the installed components NOTE Before removing the cover of your server ref...

Page 8: ...injury from hot surfaces allow the drives and the internal system components to cool before touching them 3 Identify the PCIe expansion slot in which the adapter is to be installed If a low profile option slot is to be used install the low profile bracket onto the adapter 4 Remove the expansion slot cover from the PCI Express slot 5 Firmly seat the adapter in the PCI Express slot NOTE For 1U type ...

Page 9: ... ports support either of the following DAC cables Optical Modules to be used with fiber optic cables For the maximum cable length supported see Cable specifications on page 10 To connect the HP Ethernet 10Gb 2 port 560SFP to the network 1 Orient the SFP optical module or DAC cable so that the edge connector on the edge of the circuit board is located closest to the option card circuit board 2 Inst...

Page 10: ...CR with Direct Attached Copper DAC cable SFP N A Twin Axial Copper 24 to 28 AWG depending on length and manufacturer N A N A 7 General specifications Specification Value Controller Intel 82599 Niantic Data rate 10 Gb s per port 20 Gb s combined full duplex PCI bus PCI Express x8 Gen3 Connectors Two 10 Gb SFP Dimensions LxW 13 21 cm x 6 89 cm 5 2 inches x 2 7 inches without bracket Compliance Compl...

Page 11: ...ksum Offload IPv4 IPv6 TCP Large Send Offload Receive Side Scaling Jumbo Frames up to 9000 Bytes Power and environmental specifications Specification Value Operating Temperature 0 to 55 C 32 to 131 F Humidity 10 to 90 relative humidity non condensing Non operating Temperature 65 to 85 C 85 to 185 F Humidity 5 to 95 relative humidity non condensing Power 4 W typical 9 W maximum ...

Page 12: ...r in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment int...

Page 13: ...unications products If applicable a 4 digit notified body number is inserted between CE and Please refer to the regulatory label provided on the product The point of contact for regulatory matters is Hewlett Packard GmbH Dept MS HQ TRE Herrenberger Strasse 140 71034 Boeblingen GERMANY Canadian notice Avis Canadien This Class B digital apparatus meets all requirements of the Canadian Interference C...

Page 14: ...t for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city off...

Page 15: ...tic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance ...

Page 16: ...n DAC direct attach cable IPv4 Internet Protocol version 4 IPv6 Internet Protocol version 6 PCIe peripheral component interconnect express PCI X peripheral component interconnect extended RoHS Restriction of Hazardous Substances SFP small form factor pluggable plus UDP User Datagram Protocol ...

Page 17: ...oviding documentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hp com Include the document title and part number version number or the URL when submitting your feedback ...