116
Verifying the configuration
# Execute the
display mpls lsp
command on each switch. The output shows the LSP entries. Switch B and
Switch C each have two CRLSPs. The bypass tunnel backs up the primary CRLSP.
[SwitchA] display mpls lsp
FEC Proto In/Out Label Interface/Out NHLFE
1.1.1.1/4/61400 RSVP -/1245 Vlan1
2.1.1.2 Local -/- Vlan1
[SwitchB] display mpls lsp
FEC Proto In/Out Label Interface/Out NHLFE
1.1.1.1/4/614000 RSVP 1245/3 Vlan2
Backup 1245/3 Tun5
2.2.2.2/5/30914 RSVP -/1150 Vlan2
3.2.1.2 Local -/- Vlan4
3.1.1.2 Local -/- Vlan2
[SwitchE] display mpls lsp
FEC Proto In/Out Label Interface/Out NHLFE
2.2.2.2/5/30914 RSVP 1150/3 Vlan5
3.3.1.2 Local -/- Vlan5
# Shut down the protected interface VLAN-interface 2 on the PLR (Switch B).
[SwitchB] interface vlan-interface 2
[SwitchB-Vlan-interface2] shutdown
[SwitchB-Vlan-interface2] quit
# Execute the
display interface tunnel
4 command on Switch A to display information about the primary
CRLSP. The output shows that the tunnel interface is still up. (Details not shown.)
# Execute the
display mpls te tunnel-interface
command on Switch A to display detailed information
about the tunnel interface.
[SwitchA] display mpls te tunnel-interface
Tunnel Name : Tunnel 4
Tunnel State : Up (Main CRLSP up, Shared-resource CRLSP being set up)
Tunnel Attributes :
LSP ID : 18753 Tunnel ID : 4
Admin State : Normal
Ingress LSR ID : 1.1.1.1 Egress LSR ID : 3.3.3.3
Signaling : RSVP-TE Static CRLSP Name : -
Resv Style : SE
Tunnel mode : -
Reverse-LSP name : -
Reverse-LSP LSR ID : - Reverse-LSP Tunnel ID: -
Class Type : CT0 Tunnel Bandwidth : 0 kbps
Reserved Bandwidth : 0 kbps
Setup Priority : 7 Holding Priority : 7
Affinity Attr/Mask : 0/0
Explicit Path : pri-path
Backup Explicit Path : -
Metric Type : TE
Record Route : Enabled Record Label : Enabled
FRR Flag : Enabled Bandwidth Protection : Disabled