13 Specifications
Table 13-1
Specifications
U.S.
Metric
Chassis
Height
3.74 in
95 mm
Width
10.63 in
270 mm
Depth
11.65 in
296 mm
Approximate Weight
9.23 lb
4.2 kg
Temperature Range
Operating
32° to 104°F
0° to 40°C
Nonoperating
–22° to 140°F
–30° to 60°C
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10°C/Hr. The upper limit can be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
10% to 90%
10% to 90%
Nonoperating (38.7°C max wet bulb)
5% to 95%
5% to 95%
Maximum Altitude (unpressurized)
Operating
10,000 ft
3048 m
Nonoperating
30,000 ft
9144 m
Power Supply
Output
180 W
Efficiency
Up to 85%
Operating Voltage Range
90 V ac to 264 V ac
Rated Voltage Range
100 V ac to 240 V ac
Rated Line Frequency
50 Hz to 60 Hz
Operating Line Frequency
47 Hz to 63 Hz
1
This system uses an active power factor-corrected power supply. This allows the system to pass the CE mark requirements for use in
the countries of the European Union. The active power factor-corrected power supply also has the added benefit of not requiring an
input voltage range select switch.