Storage agents 70
•
cpqDaTapeDrvBusIndex
•
cpqDaTapeDrvScsiIdIndex
•
cpqDaTapeDrvLunIndex
•
cpqDaTapeDrvName
•
cpqDaTapeDrvFwRev
•
cpqDaTapeDrvSerialNumber
Supporting SNMP Trap Description: “Cleaning is needed for the tape drive.”
NT Event ID: 1211 (Hex)0x843504bb (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Replace Cleaning Tape.
Log Message: The cleaning tape in the tape drive in %4, SCSI bus %5, SCSI target %6 needs to be
replaced.
SNMP Trap: cpqDa6TapeDriveCleanTapeReplace - 3045 in CPQIDA.MIB
Symptom: Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader
tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new
cleaning tape.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaCntlrHwLocation
•
cpqDaTapeDrvCntlrIndex
•
cpqDaTapeDrvBusIndex
•
cpqDaTapeDrvScsiIdIndex
•
cpqDaTapeDrvLunIndex
•
cpqDaTapeDrvName
•
cpqDaTapeDrvFwRev
•
cpqDaTapeDrvSerialNumber
Supporting SNMP Trap Description: “Cleaning tape needs replacing.”
NT Event ID: 1212 (Hex)0x843504bc (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a
new status of %2.
SNMP Trap: cpqSs5FanStatusChange - 8026 in CPQSTSYS.MIB
Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a
storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags