Storage agents 55
•
cpqDaTapeLibraryScsiLun
•
cpqDaTapeLibraryDoorStatus
Supporting SNMP Trap Description: “The door is [cpqDaTapeLibraryDoorStatus] for tape library.”
NT Event ID: 1182 (Hex)0x8435049e (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Status Change.
Log Message: The tape drive in slot %4, SCSI bus %5, SCSI target %6 has a new status of %7.
SNMP Trap: cpqDa2TapeDriveStatusChange - 3032 in CPQIDA.MIB
Symptom: Tape Drive Status Change. This trap indicates that the agent has detected a change in the
status of a tape drive. The variable cpqDaTapeDrvStatus indicates the current tape status. The variable
cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive.
User Action: If the tape is failed, check the tape and all SCSI connections.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaTapeDrvCntlrIndex
•
cpqDaTapeDrvBusIndex
•
cpqDaTapeDrvScsiIdIndex
•
cpqDaTapeDrvLunIndex
•
cpqDaTapeDrvName
•
cpqDaTapeDrvFwRev
•
cpqDaTapeDrvSerialNumber
•
cpqDaTapeDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqDaTapeDrvStatus] for a tape drive.”
NT Event ID: 1183 (Hex)0x8435049f (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Cleaning Required.
Log Message: The tape drive in slot %4, SCSI bus %5, SCSI target %6 requires cleaning.
SNMP Trap: cpqDaTapeDriveCleaningRequired - 3023 in CPQIDA.MIB
Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have
a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaTapeDrvCntlrIndex
•
cpqDaTapeDrvBusIndex
•
cpqDaTapeDrvScsiIdIndex
•
cpqDaTapeDrvLunIndex
Supporting SNMP Trap Description: “Cleaning is needed for the tape drive.”