5
WIRE CONNECTION
While charging a 12V storage battery, please connect the charging clamp (marked 1) to the middle
connection (marked 12V).
While charging a 24V storage battery, please connect the charging clamp (marked 1) to the right
connection (marked 24V).
MAINTENANCE
● Regu
lar maintenance and repair work will ensure proper function and compliance with the safety
requirements.
● Any improper or incorrect operation may cause failure and damage to the machine.
● The warranty period for the machine is one year commencing from th
e date of purchase. Within this
time, users can take the machine with the invoice to the distributor or the designated department for repair.
● Before the maintenance work for machine is started, the operator must turn off the main power and the
power switch of the machine.
● If the transformer is heating and no current is available from the transformer due to the over current
while of charging, the over-heat protection device inside the charger was tripped to protect the transformer.
In this case, the user should wait until the transformer is cooled before resuming the charging process.
DIAGRAM FOR CURRENT REGULATING
CHARGE 1 MIN
START 2 MAX
CHARGING CURRENT
POSITION
SWITCH LACATION
1
CHARGE——MIN——1
2
CHARGE——MIN——2
3
CHARGE——MAX
START
START