Parameters
11
Changing the scale
Setting the scale to Fahrenheit scale
Press the SET key to display
“c - F” “ c”.
Press and hold the SET key until the set using temperature is displayed. The scale
was changed to Fahrenheit scale. Hide the “
℃
” stamped on the panel.
Press the
▲
key to change to
“c - F” “ F”.
If change to Celsius scale from
Fahrenheit scale, use the
▼
key.
Temperature is displayed by Celsius scale. This can be changed to Fahrenheit scale if
desired.
Press and hold the SET key until
the display turns to “tPn” after
temperature blinks.
Displayed
Range
- - - ,
3—100
0—999
- - - ,
0.3—30
(SSt+50)
—450
0—4
-50—50
0—(Pt-50)
0.00—999
0—20.0
- - - ,
3—100
on/off
c/F
Shipping default setting
50
60
- - -
250
1
0
200
5
2.0
c
50
on
Term (display panel letters)
Set using temperature
Revise No. (tPn)
Temperature
calibration (cAL)
Sleep temperature (SSt)
Sleep start time (ct)
Sleep sensitivity (dIF)
Auto power off start time
(SUt)
Upper limit (H)
Lower limit (L)
Buzzer (bUZ)
Changing the scale
Soldering time (At)
Display panel
Unit
℃
minute
second
℃
ー
℃
℃
minute
℃
℃
ー