7.2 Storage and Transportation 

Hoymiles packages and protects individual components using suitable means to make the transport 
and subsequent handling easier. Transportation of the equipment, especially by road, must be carried 
out  by  suitable  ways  for  protecting  the  components  (in  particular,  the  electronic  components)  from 
violent, shocks, humidity, vibration, etc. Please dispose the packaging elements in appropriate ways 
to avoid unforeseen injury. 

It  is  the  customer’s  responsibility  to  examine  the  condition  of  the  components  transported.  Once 
receiving the Microinverter, it is necessary to check the container for any external damage and verify 
receipt  of  all  items.  Call  the  delivering  carrier  immediately  if  damage  or  shortage  is  detected.  If 
inspection  reveals  damage  to  the  inverter,  contact  the  supplier,  or  authorized  distributor  for  a 
repair/return determination and instructions regarding the process.   

The microinverter storage temperature is -40-85

 

7.3 Disposal 

If the equipment is not used immediately or is stored for long periods, check that it is correctly 
packed.  The  equipment  must  be  stored  in  well-ventilated  indoor  areas  that  do  not  have 
characteristics that might damage the components of the equipment. 

Take a complete inspection when restarting after a long time or prolonged stop. 

Please  dispose  the  equipment  properly  after  scrapping,  which  are  potentially  harmful  to  the 
environment, in accordance with the regulations in force in the country of installation.

 

8. Compliance Consideration 

8.1 Earth Fault Alarm Notification 

This inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm monitoring. 

If an Earth Fault Alarm occurs, the LED on the microinverter will light up solid red every 0.5 second. 

An  external  indication  of  earth  fault  alarm  can  be  provided  by  the  connecting  the  PV  System  to 
Hoymiles monitoring app/portal. For details of how to configure monitoring please refer to document 

HMP Operating Guide (Webpage) V2.0

  and 

HMP Operation Guide (APP)

.   

8.2 Power Quality Response Modes 

This  inverter  supports  the  following  power  quality  response  modes  as  per AS  4777.2:2015:  Power 
derating for voltage variation (Volt-Watt mode). 

The inverter output power varies in response to the voltage at its terminal. This mode can be enabled 
via gridprofile module on Hoymiles monitoring platform. Please refer to document 

HMP Operating 

Summary of Contents for HM-500T

Page 1: ...Version 1 0 April 2020...

Page 2: ...control the production of a single photovoltaic module directly consequently improving the flexibility and reliability of the system About the Manual This manual contains important instructions for t...

Page 3: ...nals Introduction 8 3 4 Dimension mm 8 4 About Function 9 4 1 Work Mode 9 5 About Installation 9 5 1 Accessories 9 5 2 Installation Precaution 9 5 3 Space Distance Required 10 5 4 Preparation 10 5 5 P...

Page 4: ...ification 22 8 2 Power Quality Response Modes 22 8 3 DRM 23 9 Technical Data 23 9 1 DC Input 24 9 2 AC Output 24 9 3 Efficiency Safety and Protection 24 9 4 Mechanical Data 24 9 5 Features 25 Appendix...

Page 5: ...ls Used The safety symbols in this user manual are show as below 2 About Safety 2 1 Important Safety Instructions The HM 500T HM 600T HM 700T HM 800T Microinverter is designed and tested according to...

Page 6: ...sconnect switches and Over current Protection Devices OCPD Only one photo voltaic module can be connected to one input of the inverter Do not connect batteries or other sources of power supply The inv...

Page 7: ...e limits for CE EMC which can provide reasonable protection against harmful energy However if not installed according to the instructions the microinverter may cause harmful interference to radio equi...

Page 8: ...6 50 peak efficiency 96 70 in 2015 3 2 Highlights Maximum output power up to 500W 600W 700W 800W Adapted to 60 72 cells PV panels Peak efficiency 96 70 CEC weighted efficiency 96 50 Static MPPT effici...

Page 9: ...current condition is contradicted with Microinverter operating requirement No house loads or the Export control value has been set as 0 on the DTU under the Zero Export Control mode 5 About Installati...

Page 10: ...f for better communication with Hoymiles DTU Please contact with Hoymiles technical engineer if there is any special circumstance 5 4 Preparation Installation of the equipment is carried out based on...

Page 11: ...orrect operation of electronic equipment When choosing the position of installation comply with the following conditions Install only on structures specifically conceived for photovoltaic modules supp...

Page 12: ...ation Steps Step 1 Fix Microinverter on the Rail A Mark the approximate center of each panel on the frame B Fix the screw on the rail C Hang the microinverter on the screw shown as picture below and t...

Page 13: ...AC connector unlock tool and insert the tool into the side of AC port Step 3 Install AC End Cable A Prepare the AC end cable with the proper length and insert one side of the cable into the cap Match...

Page 14: ...HM 500T HM 600T HM 700T HM 800T B Affix the serial number label to the respective location on the installation map Step 5 Connect PV Modules A Mount the PV modules above the microinverter B Connect t...

Page 15: ...dissipation 3 If both the ventilation and ambient temperature meet the requirements contact your dealer or Hoymiles technical support 125 Grid configuration parameter error 1 Check if the grid config...

Page 16: ...2 If the alarm occurs frequently check whether the grid voltage is within the acceptable range If no contact the local power operator or change the grid overvoltage protection limit via Hoymiles moni...

Page 17: ...or equal to the maximum input voltage 2 If the PV module open circuit voltage is within the normal range contact your dealer or Hoymiles technical support 206 Input port2 overvoltage 1 Please make sur...

Page 18: ...occurs accidentally and the microinverter can still work normally no special treatment is required 2 If the alarm occurs frequently and cannot be recovered contact your dealer or Hoymiles technical s...

Page 19: ...roinverter follow the steps in the order shown 1 Verify the utility voltage and frequency are within ranges shown in the in appendix Technical Data of this microinverter 2 Check the connection to the...

Page 20: ...d insulation the Microinverters are not designed to allow internal repairs The AC output wiring harness AC drop cable on the Microinverter cannot be replaced If the cord is damaged the equipment shoul...

Page 21: ...eps to install the replacement unit Go to the monitoring platform if customer already register this station online please access the Device List page and find the device that you just replaced Please...

Page 22: ...long periods check that it is correctly packed The equipment must be stored in well ventilated indoor areas that do not have characteristics that might damage the components of the equipment Take a co...

Page 23: ...lowing before installing Hoymiles Microinverter System Verify that the voltage and current specifications of the PV module must match those of the microinverter The maximum open circuit voltage rating...

Page 24: ...800T Rated output apparent power VA 500 600 700 800 Rated output current A 2 17 230V 2 08 240V 2 61 230V 2 50 240V 3 04 230V 2 92 240V 3 48 230V 3 33 240V Nominal output voltage range V 230 180 275 24...

Page 25: ...70 28 250 170 28 250 170 28 Weight kg 2 6 2 6 2 6 2 6 Enclosure rating Outdoor NEMA IP67 Cooling Natural convection No fans Model HM 500T HM 600T HM 700T HM 800T Communication 2 4GHz Proprietary RF No...

Page 26: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 26 HM 500T HM 600T HM 700T HM 800T Appendix 1 Installation Map...

Page 27: ...ix 2 WIRING DIAGRAM 230VAC SINGLE PHASE UP TO 6 HM 800s PER AC BRANCH CIRCUIT GROUND NEUTRAL W AC DISTRIBUTION PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREEN G BRANCH END CAP L1 P...

Page 28: ...0s PER AC BRANCH CIRCUIT UP TO 6 HM 800s PER AC BRANCH CIRCUIT UP TO 6 HM 800s PER AC BRANCH CIRCUIT GROUND NEUTRAL W AC DISTRIBUTION PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREE...

Reviews: