7.2 Storage and Transportation
Hoymiles packages and protects individual components using suitable means to make the transport
and subsequent handling easier. Transportation of the equipment, especially by road, must be carried
out by suitable ways for protecting the components (in particular, the electronic components) from
violent, shocks, humidity, vibration, etc. Please dispose the packaging elements in appropriate ways
to avoid unforeseen injury.
It is the customer’s responsibility to examine the condition of the components transported. Once
receiving the Microinverter, it is necessary to check the container for any external damage and verify
receipt of all items. Call the delivering carrier immediately if damage or shortage is detected. If
inspection reveals damage to the inverter, contact the supplier, or authorized distributor for a
repair/return determination and instructions regarding the process.
The microinverter storage temperature is -40-85
℃
.
7.3 Disposal
-
If the equipment is not used immediately or is stored for long periods, check that it is correctly
packed. The equipment must be stored in well-ventilated indoor areas that do not have
characteristics that might damage the components of the equipment.
-
Take a complete inspection when restarting after a long time or prolonged stop.
-
Please dispose the equipment properly after scrapping, which are potentially harmful to the
environment, in accordance with the regulations in force in the country of installation.
8. Compliance Consideration
8.1 Earth Fault Alarm Notification
This inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm monitoring.
If an Earth Fault Alarm occurs, the LED on the microinverter will light up solid red every 0.5 second.
An external indication of earth fault alarm can be provided by the connecting the PV System to
Hoymiles monitoring app/portal. For details of how to configure monitoring please refer to document
“
HMP Operating Guide (Webpage) V2.0
”
and
“
HMP Operation Guide (APP)
”
.
8.2 Power Quality Response Modes
This inverter supports the following power quality response modes as per AS 4777.2:2015: Power
derating for voltage variation (Volt-Watt mode).
The inverter output power varies in response to the voltage at its terminal. This mode can be enabled
via gridprofile module on Hoymiles monitoring platform. Please refer to document
“
HMP Operating