14 Trouble Shooting Chart
51
PROBLEM
PROBABLE CAUSE
REMEDY
Repair speed reducer
Ice blade frozen to evaporator
during power failure.
Electronic overload may
be set too high. Adjust so
it will trip upon overload
condition before
damaging gearbox, motor
or coupling.
Repair speed reducer.
peed Reducer output shaft
broken, motor burnt out
or off on overload.
Operating ice flaker for an
extensive period of time with
dull ice blade causing excessive
chatter.
Replace ice blade with
new stainless steel blade,
also replace flexible
coupling.
Repair or replace speed
reducer.
Summary of Contents for Rapid Freeze
Page 6: ......
Page 16: ...6 SEAWATER MODEL INSTALLATION 10 ASSEMBLY DRAWING 11ESS 21ESS...
Page 17: ...6 SEAWATER MODEL INSTALLATION 11 ASSEMBLY DRAWING 31ES 31ESS...
Page 18: ...6 SEAWATER MODEL INSTALLATION 12 ASSEMBLY DRAWING 51ES 51ESS...
Page 19: ...6 SEAWATER MODEL INSTALLATION 13 ASSEMBLY DRAWING 11EFS 21EFS...
Page 20: ...6 SEAWATER MODEL INSTALLATION 14 ASSEMBLY DRAWING 51EFS...
Page 21: ...6 SEAWATER MODEL INSTALLATION 15 ASSEMBLY DRAWING 10ESS 20ESS...
Page 22: ...6 SEAWATER MODEL INSTALLATION 16 ASSEMBLY DRAWING 30ES 30ESS...
Page 23: ...6 SEAWATER MODEL INSTALLATION 17 ASSEMBLY DRAWING 50ES 50ESS...
Page 28: ...9 How The Rapid Freeze Flaker Operates 22 ICE FLAKER CUTAWAY DRAWING EXHIBIT 26...
Page 38: ...12 Control Panel Wiring Diagrams 32 Control Panel Schematic E20T40 RL...
Page 39: ...12 Control Panel Wiring Diagrams 33 460 3 60 WIRING E20T47...
Page 42: ...12 Control Panel Wiring Diagrams 36 220 1 50 Control Panel Schematic E20T40 RL 50...
Page 43: ...12 Control Panel Wiring Diagrams 37 380 3 50 Control Panel Schematic E20T60...
Page 64: ...15 Service Adjustment 58 EXHIBIT 40...