background image

Electromagnetic Compatibility Chart

HOVER

MATT

®

 

USER MANUAL

14

Rev A

HMManual

 

EMC:  Table 4 

 

Recommended separation distances between portable and mobile RF 

communications equipment and the HoverTech International Air Supply 

 

 

The HoverTech International Air Supply is intended for use in an electromagnetic environment in 

which radiated RF disturbances are controlled.  The customer or the user of the HoverTech 

International Air Supply can help prevent electromagnetic interference by maintaining a minimum 

distance between portable and mobile RF communications equipment (transmitters) and the 

HoverTech International Air Supply as recommended below, according to the maximum output power 

of the communications equipment. 

 
 

Rated maximum 

output power of 

transmitter 

 

Separation distance according to frequency of transmitter 

m

 

15 kHz to 80 MHz 

d=[3.5/V

1

]

80 MHz to 800 MHz 

d=[3.5/V

1

]

800 MHz to 2.5 GHz 

d=[7/E

1

]

0.01 

0.12 

0.12 

0.23 

0.10 

.38 

.38 

0.73 

1.2 

1.2 

2.3 

10 

3.8 

3.8 

7.3 

100 

12 

12 

23 

For transmitters rated at a maximum output power not listed above, the recommended separation 

distance d in meters (m) can be estimated using the equation applicable to the frequency of the 

transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to 

the transmitter manufacturer. 

 

NOTE 1

: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. 

 

NOTE 2

: These guidelines may not apply in all situations.  Electromagnetic propagation is affected by 

absorption and reflection from structures, objects, and people.

  

 

For HTAIR-2300 ONLY

Summary of Contents for hovermatt

Page 1: ...ility Chart 11 14 Cleaning 15 Preventative Maintenance Infection Control 16 Frequently Asked Questions 17 Symbol References 02 Intended Use and Precautions 03 Components Parts List 29 Warranty Statement 30 31 Returns and Repairs 32 Part Identification 19 Power Cord Clamp Replacement 20 Handle Replacement 21 Feet or Bumper Replacement 22 Hose Removal 23 Air Filter and Air Filter Cover Replacement 2...

Page 2: ... Functional Earth Ground Alternating Current Date of Manufacture Underwriters Laboratory Agency Approval 120 V Medical Equipment with respect to electrical shock fire and mechanical hazards only in accordance with UL 60601 1 IEC EN 60601 1 CAN CSA C22 2 No 601 1 230 V Medical Equipment with respect to electrical shock fire and mechanical hazards only in accordance with UL 60601 1 IEC 60601 1 2 CAN...

Page 3: ...ing a patient over 750 lbs 340kg Never attempt to move a patient on an uninflated HoverTech mattress Caregivers must verify that the opposite side rail on the receiving surface is in an upright and locked position prior to transfer Route the power cord in a manner to ensure freedom from hazard Avoid blocking the air intakes of the air supply Never leave patient unattended on an inflated device Use...

Page 4: ...supply will inflate the mattress At the same time the air is supporting the patient the air is escaping from the perforations in the underside of the Hover Matt transfer mattress The escaping air acts as a lubricant to reduce friction which facilitates effortless transfers With less force needed to transfer a patient there is less physical effort and strain expended by caregivers which results in ...

Page 5: ...Transfer Handles 6 Single Patient Use Transfer Handles 8 Air Supply Hose Attaches to Either Side Snap on HoverMatt Flap Connects to Snap on Hose End Close Flap to Secure Patient Safety Straps 2 DO NOT USE TO TRANSFER Label Includes Model Serial and Instructions for Use ...

Page 6: ... USER MANUAL 6 Rev A HMManual Part Identification Air Supply Air Filter Cover Hose Nozzle Hose Hose Release Button Control Panel Label Carrying Handle Attachment Hook Power Cord Strap Power Cord US UK Euro Aust ...

Page 7: ...ir flow NOTE The LED will indicate the inflation speed by the number of flashes i e two flashes equals the second inflation speed All of the settings in the Adjustable range are substantially lower than the HoverMatt and HoverJack settings The Adjustable function is not to be used for transferring it is only for use with HoverTech Accessories which require a lower pressure for slow inflation Stand...

Page 8: ...se nozzle into mattress in one of the two entries located parallel to the foot end and snap in place 5 Be sure transfer surfaces are as close as possible and brake the wheels 6 If possible transfer from a higher surface to a lower surface 7 Turn on air supply by choosing the appropriate speed based on the mattress width 8 Grasp transfer handles and pull patient on an angle either head first or fee...

Page 9: ...gainst ingress of water Ordinary not protected Mode of operation CONTINUOUS OPERATION To remove supply mains unplug equipment from wall Patient Weight Limit 1 200lbs 544kg Use Temperature 50 to 104 F 10 to 40 C Use Humidity 10 to 70 Non Condensing Storage Shipping Temperature 40 to 176 F 40 to 80 C Storage Shipping Humidity 10 to 70 Non Condensing Power Input 120 V 60 Hz 10 A North American versio...

Page 10: ...overTech International Products are Latex Free RE USABLE HOVERMATT AIR TRANSFER SYSTEM SINGLE PATIENT USE HOVERMATT AIR TRANSFER SYSTEM Material Nylon Twill Nylon Twill Non Woven Construction RF Welded Sewn Width 28 71 cm 34 86 cm 39 99 cm or 50 127 cm 34 86 cm 39 99 cm Length 78 198 cm 78 198 cm Part HTAIR2300 Australian Version For a full product listing go to www statina com au ...

Page 11: ...ment Guidance RF emissions CISPR11 Group 1 The HoverTech International Air Supply uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR11 Class A The HoverTech International Air Supply is suitable for use in all establishments other than domestic and those directly connect...

Page 12: ... environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT For 0 5 cycle 40 UT 60 dip in UT For 5 cycles 70 UT 30 dip in UT For 25 cycles 5 ...

Page 13: ...separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each frequency rangeb Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHZ and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Elect...

Page 14: ...communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 15 kHz to 80 MHz d 3 5 V1 P 80 MHz to 800 MHz d 3 5 V1 P 800 MHz to 2 5 GHz d 7 E1 P 0 01 0 12 0 12 0 23 0 10 38 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in m...

Page 15: ...rying temperature should never exceed 115 degrees Fahrenheit 46 C The backing of the nylon is poly urethane and will begin to deteriorate after repeated high temperature drying The Double Coated HoverMatt transfer mattress should not be put in the dryer To help keep the HoverMatt transfer mattress clean HoverTech International recommends the use of their disposable or re usable protector sheets A ...

Page 16: ...ress is used on an isolation patient the hospital should employ the same protocols procedures it utilizes for the bed mattress and or for the linen in that patient room Infection Control Prior to use a visual inspection should be performed on the HoverMatt air transfer system to insure the air supply power cord is not frayed or nicked and that there is no visual damage that would render the air su...

Page 17: ...he HoverMatt air transfer system is 1 200lbs 544kg It is available in four different widths to accommodate the body mass of the patient 2 Is the HoverMatt air transfer system latex free Yes Statina Healthcare Australia is registered with the TGA The HoverMatt air transfer system is listed as ARTG AUST L 79807 3 Is the HoverMatt air transfer system TGA Approved ...

Page 18: ...HOVERMATT USER MANUAL 18 Rev A HMManual AIR SUPPLY NO USER SERVICEABLE PARTS Only qualified service personnel shall perform repairs on the HoverTech International Air Supply ...

Page 19: ...achment Hook Dust Cover Hose Attachment Snap Air Filter Air Filter Cover Hose Bumpers Power Cord Power Cord Strap Foot Information Labels Power Cord Clamp Grounding Pin Used for a Ground Continuity Bond Test Circuit Breakers Metal Cover Control Panel Label US UK Euro Aust ...

Page 20: ...HOVERMATT USER MANUAL 20 Rev A HMManual Power Cord Clamp Replacement ...

Page 21: ... the barrel nut using two 5 32 allen wrenches as shown 2 Attach the new handle by reversing the process When tightening the screw be sure that the handle can rotate easily The screw is treated with thread lock to secure it in place Carrying Handle Attachment Hook 5 32 Allen Wrench 5 32 Allen Wrench Socket Head Screw Barrel Nut ...

Page 22: ...lace by a self adhesive backing Use a small flat bladed screwdriver to pry up an edge and gently remove the foot or bumper 2 Clean surface thoroughly to remove any excess adhesive that may have been left behind Apply the new part by removing the backing material and position as shown Press firmly to ensure adhesion ...

Page 23: ...d hose by lifting the dust cover slightly and unsnapping the hose from the side of the unit as shown 2 Push the release button at the top of the unit to remove the hose 3 Attach the new hose by reversing the process Hose Release Button Dust Cover Hose Attach ment Snap Hose ...

Page 24: ...each side to detach the air filter covers 3 Re attach the new air filter covers and screws 1 Follow the steps shown above to remove air filter covers 2 Remove air filters and replace 3 Re attach the air filter covers and screws For air filter cleaning instructions please refer to Page 16 To Remove Air Filter Covers To Remove Air Filters Air Filter Air Filter Cover ...

Page 25: ...3 2 Lift the cover flap to remove the 3 phillips head screws that attach the dust cover 3 To replace dust cover fold in the three flexible tabs Then insert the screws one at a time starting with the top middle followed by the sides 1 Disconnect hose from unit See page 23 2 Remove the phillips head screw and snap To Remove Dust Cover To Remove Hose Attachment Snap ...

Page 26: ...head screws on each side to detach the air filter covers Remove the air filters 3 Gently pull the damaged cover apart to allow clearance to remove it 4 Carefully re insert the new metal cover Reassemble the two filters and filter covers 5 Secure everything in place by reinserting four screws Air Filter Air Filter Cover Metal Cover ...

Page 27: ...HMManual Cord Strap Replacement 1 Unsnap the strap and remove power cord 2 Detach the damaged cord strap by removing the screw as shown 3 Reattach strap by positioning in place and securing it with the screw provided Power Cord Strap ...

Page 28: ... e s s u r e L o w Verify AC from wall X X X Check power cord connections at air supply and wall Check circuit breakers on rear of air supply unit X Return unit for repair X Return unit for repair X Return unit for repair X Check hose connections at air supply and mattress Check hose for rips tears Check mattress for rips tears Verify that air filters are clean ...

Page 29: ...HOVERMATT USER MANUAL 29 Rev A HMManual Component Parts List ...

Page 30: ...is not an unconditional guarantee for the life of the product Our warranty does not cover product damage that may result from use contrary to Manufacturer s instructions or specifications misuse abuse tampering or damage due to mishandling Warranty specifically does not cover product damage that may result from using an air supply that produces more than 3 5 psi to inflate the HoverMatt air transf...

Page 31: ...xtend beyond this warranty statement The provisions of these warranty clauses are in lieu of all other warranties expressed or is no warranty that the goods will be fit for a particular purpose By accepting the goods the buyer acknowledges that buyer has determined the goods are suitable for the buyer s purposes MANUFACTURER S SPECIFICATIONS ARE SUBJECT TO CHANGE Statina Healthcare s liability und...

Page 32: ...r repairs is approximately 2 weeks A fee of 50 will be assessed if HoverMatt air transfer systems are not properly cleaned for repair All products should be sent to Attn Repair Dept RGA _______ All products being returned to Statina Healthcare Australia must have a Return Goods Authorization Number issued from the company Please call 1300 365 404 for an RGA each repair Should a repair charge be as...

Page 33: ...3 30 Leighton Place Hornsby NSW 2077 Phone 1300 365 404 www statina com au ...

Reviews: