7

4 205 534  / 00

4.  Functional principle of the heating system

 

Component 

Function

 

Gas heating boiler 

Burns natural gas safely without harming 
the environment. Removes heat from the 
exhaust  gas  generated  by  combustion 
and transfers it to the heating water. 

 

Water heater 

It holds a reserve of domestic hot water 
for consumption (e.g. for showering).

 

Boiler control 

Controls  and  monitors  operation  of  the 
heating boiler. Ensures that, whatever the 
temperature outside, the room tempera-
ture is as required – in an optimum and 
fuelefficient manner.

 

Radiators, underfloor heating 

Delivers the heat from the heating water 
to the room.

 

Heating pump 

Pumps the heating water from the boiler to 
the radiators and back to the boiler, where 
it is heated up again.

 

Mixer valve 

Changes  the  heater  flow  temperature 
by  mixing  in  colder  heater  return  water 
(water that flows to the radiator), so that 
the desired room temperature is achieved 
regardless of the outside temperature.

 

Manometer 

Indicates the water pressure in the heating 
system.

 

Vent 

Ensures that only heating water and no air 
is in the system or heaters.

 

Safety valve 

Prevents  pressure  in  the  system  beco-
ming excessive.

 

Membrane expansion vessel 

Keeps  the  pressure  in  the  system  con-
stant. 

4. 

Functional principle of the heating system

Summary of Contents for TopGas classic 12

Page 1: ...7 EN Subject to modifications Hoval United Kingdom Hoval LTD Northgate Newark Nottinghamshire NG24 1JN Phone 44 1636 67 27 11 Fax 44 1636 67 35 32 Hoval Export Hovalwerk AG Austrasse 70 9490 Vaduz Pri...

Page 2: ...Functional principle of the heating system 7 8 5 System start up 8 5 1 Checks prior to start up 8 5 2 Switching on the system 8 6 Heating system control 9 6 1 Operating elements of the boiler control...

Page 3: ...elephone numbers Heating installer Plumbing installer Electrical installer Chimney inspector Fuel supplier 1 2 Key to symbols used i Instruction Prompts you to carry out an action Result Shows the exp...

Page 4: ...equipment Yes No Condensate pump Yes No Outside temperature sensor Yes No Room temperature sensor Yes No Room air dependent Yes No Room air independent Yes No Number of heating circuits 1 2 3 4 Heatin...

Page 5: ...This does not apply if your system is operated independent of boiler room air Commissioning of a newly installed system may only be carried out by a quali fied installer The installation control must...

Page 6: ...ce The reliable and safe functioning of a gas boiler as well as the achievement of an optimal effectiveness and clean combustion are only possible and guaranteed if the system is maintained and cleane...

Page 7: ...ner Radiators underfloor heating Delivers the heat from the heating water to the room Heating pump Pumps the heating water from the boiler to the radiators and back to the boiler where it is heated up...

Page 8: ...ning the TopGas the stench trap siphon in the conden sate drain pipe must be filled with water 5 1 Checks prior to start up Check the water level in the heating system The heating system must be fille...

Page 9: ...sure which does not cause a reaction in any of the operating modes is displayed for information only Off no heating requirement The appliance is ready for operation and will be turned on immediately w...

Page 10: ...art attempts are permitted before the unit registers a malfunction Operating Mode Heat During the heating operation the target temperature is shown in the two digit display If the service button is pr...

Page 11: ...rmation key Show the operating data on the display Return to the basic display without saving the values 7 Heating curve set up Set the heating characteristics 8 Operating mode selection key Select th...

Page 12: ...display Return to the basic display without saving the values 7 Heating curve set up Set the heating characteristics Key Designation Function 9 Display The basic display shows the day of the week dat...

Page 13: ...off frost protection activated 9 Manual mode emission measurement For heating technician only 10 Display The basic display shows the day of the week date and time of the day as well as the current bo...

Page 14: ...l for the heater control Check water level and water pressure Top off the heat system and bleed off air 15 Are the radiator valve open Open the valves The heater circ pump is not running Open the latc...

Page 15: ...ons Press the On Off button to turn the appliance off LED is dark the water pressure is displayed The heater flow and return valves must be open The boiler fill and drain faucet is accessible on the u...

Page 16: ...ng wasted You therefore save fuel if you keep windows and doors closed in winter close chimney dampers when the fire is out only operate kitchen and ba throom fans when it is necessary to remove moist...

Page 17: ...ng heating boilers for oil and wood firing burners solar energy production systems collectors and heat pumps for making use of geo thermal heat or heat generated by wind and water Heat distribution sy...

Page 18: ...7243 550 15 www hoval at Hoval Italia S r l Via per Azzano San Paolo 26 28 I 24050 Grassobbio BG Telefono 39 035 52 50 69 Telefax 39 035 52 58 58 www hoval it Germany Switzerland Austria Italy France...

Reviews: